Installation Clearances

Cooling and Duty Cycle

Source 4 LED fixtures are fan cooled and can operate all channels at full power

continuously in ambient temperatures up to 40°C (104°F).

If ambient conditions exceed 40°C (104°F) or fail to allow sufficient airflow, over a long

period of time, the fixtures may shut down and remain off until they return to a safe

operating temperature. The fixtures provide two methods to indicate over temperature that

can be set up on the Local Settings menu. The over temperature indicators are:

Visible

The LED array glows in a dull, low intensity with only some emitters illuminated, the LCD

backlight is turned on, the LCD displays Overtemp Activated, and the Error Indicator light

turns on.

Dark

The LED array turns off and the LCD displays Overtemp Activated. The LCD backlight is

not turned on.

LED life is adversely affected by high-temperature operation. When operating under

elevated ambient temperatures, avoid turning all channels to 100% for extended periods,

such as channel checks or focusing.

C A U T I O N :

Duty Cycle

Operating the fixtures in higher ambient temperatures or low-airflow situations may

cause the power supply to shut down. Following a cool-down period, the power

supply will automatically reset and the fixture will return to operation.
It is good practice to power down any device with on-board electronics to limit

unnecessary wear on the devices and eliminate residual use of electricity.