ETC Source Four HID User Manual
Source four, Lamp type and general information, Ballast information
Source Four™ HID
• 1
Source Four
™
HID
Lamp type and general information:
Do not use lamps other than the following lamp type in Source Four HID fixtures.
Use of lamps other
than specified below will void UL/cUL safety compliance and your warranty
.
•
Source Four HID is suitable for damp locations
•
Can be canopy mounted
•
No recessed mounting
Caution!
Source Four HID is
NOT
dimmable. Dimming will damage ballast and void warranty.
Ballast information
Caution!
The Source Four HID
cannot
be dimmed.
•
Acceptable voltage is 120V (+/- 10%) 50/60HZ
only
.
•
Operating current of 1.5 Amps
•
Inrush current of <14 Amps
•
Room ambient temperature should not exceed 104ºF (40ºC)
•
Lamp ignition voltage is 4.5Kv, non-hot restrike.
•
Ballast case temperature should not exceed 167ºF (75ºC)
•
The ballast is attached to the Source Four yoke by two screws, non-remotable.
Lamp Type
Manufacturing Codes
Watts
Base
Bulb
LCL
Ave.
Hrs.
Initial
lumens
Color
temp
Ceramic Metal Halide
CDM-T 150W/830
150
G12
T6
56mm
9000
14000
3000˚K
CDM-T 150W/942
150
G12
T6
56mm
9000
12700
4000˚K
MD150T6/U/G12/830
150
G12
T6
56mm
9000
14000
3000˚K
MBI150/T/30
150
G12
T7
57mm
6000
11500
3000˚K
MBI150/T/40
150
G12
T7
57mm
6000
11250
4000˚K
Table 1:
HID lamp reference
Beam focus knob
Lens tube
Shutters
Barrel
Pattern holder slot
Retainer bolt
Drop-in iris
Retaining clip
Color frame
Color frame holder
Reflector housing
Yoke locking knob
Lamp housing
Ballast
Barrel rotation knob
Yoke