beautypg.com

ETC Source Four HID User Manual

Source four, Lamp type and general information, Ballast information

background image

Source Four™ HID

• 1

Source Four

HID

Lamp type and general information:

Do not use lamps other than the following lamp type in Source Four HID fixtures.

Use of lamps other

than specified below will void UL/cUL safety compliance and your warranty

.

Source Four HID is suitable for damp locations

Can be canopy mounted

No recessed mounting

Caution!

Source Four HID is

NOT

dimmable. Dimming will damage ballast and void warranty.

Ballast information

Caution!

The Source Four HID

cannot

be dimmed.

Acceptable voltage is 120V (+/- 10%) 50/60HZ

only

.

Operating current of 1.5 Amps

Inrush current of <14 Amps

Room ambient temperature should not exceed 104ºF (40ºC)

Lamp ignition voltage is 4.5Kv, non-hot restrike.

Ballast case temperature should not exceed 167ºF (75ºC)

The ballast is attached to the Source Four yoke by two screws, non-remotable.

Lamp Type

Manufacturing Codes

Watts

Base

Bulb

LCL

Ave.

Hrs.

Initial

lumens

Color

temp

Ceramic Metal Halide

CDM-T 150W/830

150

G12

T6

56mm

9000

14000

3000˚K

CDM-T 150W/942

150

G12

T6

56mm

9000

12700

4000˚K

MD150T6/U/G12/830

150

G12

T6

56mm

9000

14000

3000˚K

MBI150/T/30

150

G12

T7

57mm

6000

11500

3000˚K

MBI150/T/40

150

G12

T7

57mm

6000

11250

4000˚K

Table 1:

HID lamp reference

Beam focus knob

Lens tube

Shutters

Barrel

Pattern holder slot

Retainer bolt

Drop-in iris

Retaining clip

Color frame

Color frame holder

Reflector housing

Yoke locking knob

Lamp housing

Ballast

Barrel rotation knob

Yoke