beautypg.com

ETC Desire Series XTI Wall Mount User Manual

Installation, Electrical, Power requirements

background image

To install the Wall Mount:

Step 1: Bolt the fixture to the Wall Mount with the provided three bolts through the holes in the base of the yoke. Use

provided anti-seize on the threaded holes in the wall bracket where the fixture is to mount.

Step 2: Do one of the following. Refer to the illustrations on the next page.

• Route the cables through the cable grips and pull the cables out the back of the mount. Install the provided

watertight hole plugs in the cord grip holes not used.

• Route the cables through the cable grips of flush or surface mounted junction boxes.

Step 3: Leave slack in the cables between the fixture and the cable grip to allow focusing of the fixture.
Step 4: Tighten the cable grips.
Step 5: Make the electrical connection to the supply cable inside the junction box.
Step 6: Attach the Wall Mount and fixture assembly to the wall.
Step 7: Attach a safety cable from the fixture to a secure location on the mounting structure.
Step 8: Make the DMX/RDM connections at the Terminal board.
Step 9: Focus the fixture.
Step 10: Tighten the mounting bolts to secure the fixture to the Wall Mount.

Installation

The Wall Mount Bracket accessory for the Desire XTI provides a stable mounting position for the fixture,

while providing a wire way for a clean and functional installation to walls and other vertical surfaces.

Install on a suitable, rigid wall. The installation must meet the published weight and wind-load requirements for the

fixture. Use application appropriate bolts, nuts, and washers such as hot-dipped zinc or stainless steel for wet

locations.
D40XTI

● Weight: 16 pounds, exclusive of accessories and/or color filters and patterns.

● Wind Load: 0.72 cubic feet of effective projected area (EPA).

D60XTI

● Weight: 23 pounds, exclusive of accessories and/or color filters and patterns.

● Wind Load: 0.95 cubic feet of effective projected area (EPA).

Use three bolts to attach the fixture to the Wall Mount. The curved holes in the yoke allow small focusing

adjustments.
Reference D40/D60XTI Installation Instructions for information about electrical requirements and installing the

fixture. The instructions include a yoke template and is available for download at

www.etcconnect.com

.

Keep the following in mind while installing the fixture and Wall Mount.

● The slots on the yoke provide small focusing adjustments.

● The fixture must be attached to the mount and the power and DMX/RDM cords pulled through the

cable grips prior to mounting the assembly on the wall.

● The Wall Mount must be securely attached to the wall directly over the junction boxes or near flush

or surface mounted junction boxes.

● Use an appropriate water-resistant sealant around the junction boxes.

● The fixture and mount assembly is heavy. Take the necessary precautions to ensure your safety.

Electrical

● The fixture must be installed by a qualified electrician.

● The fixture must be installed in accordance with national, state, and local electrical codes.

● The fixture must be grounded.

● Application-appropriate electrical junction boxes with cord grips are required.

● The junction boxes must not interfere with focusing.

● The fixture is completely pre-wired at the factory and there is no need for entry into the housing.

● The fixture must be connected to a non-dimmable power source in order to avoid damage to its internal

power supply and other electrical components. Dimming will damage the fixture and void the warranty.

Power Requirements

● Acceptable voltage is rated 100 to 240VAC 50/60 Hz universal power input.

CAUTION: The fixtures are sold for 100 to 240VAC universal power input. Verify that the

voltage requirements match the power supply. Connecting the fixture to the wrong voltage

voids the warranty.

Page 1 of 2

Corporate Headquarters 3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA Tel +608 831 4116 Fax +608 836 1736

London, UK Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK Tel +44 (0)20 8896 1000 Fax +44 (0)20 8896 2000

Rome, IT Via Pieve Torina, 48, 00156 Rome, Italy Tel +39 (06) 32 111 683 Fax +44 (0) 20 8752 8486

Holzkirchen, DE Ohmstrasse 3, 83607 Holzkirchen, Germany Tel +49 (80 24) 47 00-0 Fax +49 (80 24) 47 00-3 00

Hong Kong Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong Tel +852 2799 1220 Fax +852 2799 9325

Service: (Americas)

[email protected]

(UK)

[email protected]

(DE)

[email protected]

(Asia)

[email protected]

Web:

www.etcconnect.com

Copyright © 2014 ETC. All Rights Reserved. Product information and specifications subject to change.

7410M2150

Rev B Released 2014-02

ETC intends this document to be provided in its entirety.

Mains

Europe

North America

Line

Brown

Black

Neutral

Blue

White

Ground

Green/Yellow

Green

NOTE: Reference the Desire XTI User Manual for information for focusing and

configuring the fixture. The User Manual is available for download at

www.etcconnect.com.

WARNING:

● Do not use this fixture if glass lens is deeply scratched or cracked. Damaged lenses

must be replaced.

● Do not mount the fixture on or near combustible surfaces.
Failure to follow these warnings can result in serious injury or death.

WARNING:

● Do not use this fixture with a damaged power lead. If the power lead (cord

set) is damaged, it must be replaced.

● Do not expose the interior of the fixture to moisture. Do not stand in water

while installing or servicing the fixture.

Failure to follow these warnings can result in serious injury or death.

WARNING:

● Do not use the fixture with a damaged power lead. If the power lead (cord set) is

damaged, it must be replaced.

● Do not expose the interior of the fixture to moisture. Do not stand in water while

installing or servicing the fixture.

Failure to follow these warnings can result in serious injury or death.

D40/D60 XTI Wall Mounting

Desire Series by ETC Installation Guide

NOTE: The EPA number is obtained by estimating Cd (wind drag coefficient) and

multiplying it with the projected ara of the object. Wind drag coefficients were obtained

from AASHTO sixth edition 2013.