2N TELEKOMUNIKACE a.s., www.2n.cz

®

1.

2.

Enter the programming mode via the voice menu (incoming call or machine room
Audio Unit) and set the shaft number to the ALARM memory (011–016). Then
choose parameter 017 (refer to the Table of Parameters) and add the required
character (#) to one of the ALARM memories.

Caution

Configure the alarm-intercom connection for calls to the machine room
Audio Unit of any shaft (1–8).
Identically, configure the machine room – control centre connection for
ALARM set 2.
Make sure that the control centre Audio Unit is of the machine
room type.
You can use confirmation mode 1 or 2 for calling to a machine room Audio
Unit. With the other options (3–6), the call is processed as if 1 was
selected.

Note

It is possible to combine calling to the machine room (control centre)
Audio Unit with calling via the PSTN, GSM, UMTS and VoIP networks
(depending on the module used).
To set up a check call to a machine room Audio Unit, you can set the
number as described in the Alarm – Intercom subsection above.