Configure lift 2–8 as 2–8 (set the switch to position 5 for lift 5, e.g.).

Audio Unit Connection

Connect up to 5 Audio Units to each splitter. As the splitter has only 3 audio unit
terminals, connect 1–2 Audio Units in parallel. Remove the slide-on terminals from the
audio unit connectors and connect the twin-wire. Adhere to polarity to avoid the Audio

Refer to the schemes printed on the splitter and Audio Unit for t

Unit error.

he

connection polarity.

Requirements

Connect up to 2 Audio Units to one terminal.
With multi-strand cables, always use a pair of wires which match each other. In
standard UTP cables the paired wires are twisted around each other.
With special cables (to the cabin), use the neighbouring wires and make sure
that the nearest surrounding wires do not radiate interference (power wire, video
signal etc.).

Recommendation

Do not run the bus near power wires, especially long sections.

.

Branch the bus to shorten the total length of sections

Lift Blocking Function Connection

Lift blocking is enabled by the contact breaking (opening) when there is a telephone
line (PSTN, GSM, UMTS) fault or if the

rechargeable batteries are almost

2N Lift8

®

flat. Connect the contact to the relevant input of the control electronics of the lift/group
of lifts. The control electronics must ensure that, after the contact opening, the lifts in
operation go down to the nearest station and the doors open.

Termination Resistance

Warning

The bus is electrically isolated from the telephone line circuits according to
the EN60950 standard requirements and its low voltage cannot cause any
electrical accident.

Caution

This function may be mandatory depending on the regulations applicable

and time of installation.

for the given country

Caution

There is one more pin between the main bus connector and lift number
configuration, which helps you configure the termination resistance on the
last splitter connected (the furthest from the

).

CU

The termination resistance jumper is disabled by default.