2N Lift8 v1.5.2 User Manual
Page 135

135
General
Set the standard lift parameters in the General menu. The first row signals the
Authorisation state of the selected lift. All the lifts added manually to the database or
created automatically yet confirmed as real lifts are authorised. Contact number is the
number for
identification and
check calls: enter either a SIM card in the
CU
2N Lift8
®
, number of the PSTN line to the
or number of the PBX/gateway behind which
CU
CU
the
is located. Type defines the type of device:
,
,
CU
2N
LiftNet
®
2N SingleTalk
®
2N
or
. Refer to the lift creating subsection above for details. Name
Lift8
®
Unknown
helps you define the lift name. Set a name equal to the contact number for an
automatically created lift. Lift identification is primarily used by the CPC a P100
protocols for counterparty authorisation. As identification is not set automatically
during creation, complete the value to make the two protocols work properly. In the
case of check call rejection/confirmation with a DTMF character, this parameter is not
checked. Enter the address of the building in which the CU is located into the Address
field to display this information on the map used by a technician for repairs or
dispatcher for rescue team navigation. Fill in brief information on the lift to be installed
in the Description item: location, purpose, specific settings and so on.
Figure:
Lifts – General Menu
The Check call period specifies the check call timeout. The lift can call the
2N Lift8
®
any time within this timeout, but having exceeded this value, it will be marked
Server
as defective. The non-functional status will be removed when another check or alarm
call arrives in the server from this lift. The default value of this parameter is 72 hours.
The Alarm call response specifies the type of alarm call processing:
,
Normal call
and
Similarly, the Check call
Confirm with 1, CPC Antenna, CPC KONE
P100.
response specifies the type of check call processing:
,
,
Reject Accept and send 5