SECTION 6 - JLG CONTROL SYSTEM
3121180
– JLG Lift –
6-55
DATALOG:
ON
XXXXhXXm
Total controller on (EMS) time
ENGINE
XXXXhXXm
Engine run time
DRIVE
XXXXhXXm
Total controller drive operation time
LIFT
XXXXhXXm
Total controller lift operation time
SWING
XXXXhXXm
Total controller swing operation time
TELE
XXXXhXXm
Total controller telescope operation time
MAX TEMP
XXC
Maximum measured ambient temp.
MIN TEMP
XXC
Minimum measured ambient temp.
MAX volts
XX.XV
Maximum measured battery voltage
RENTAL
XXXXhXXm
Total controller operation time. NOTE: can be reset
ERASE RENTAL?
Not available at Access Level 2.
ENTER resets rental data log time to zero.
VERSIONS:
GM SW
PX.X
Ground module software version
GM HW REV
XXXX
Ground module hardware revision
GM SN
XXXXXX
Ground module serial number
PM SW
PX.X
Platform module software version
PM HW REV
XXXX
Platform module hardware revision
PM SN
XXXXXX
Platform module serial number
cm sw
PX.X
Chassis module software version
bm sw
PX.X
BLAM module software version
c pin SW
Cylinder moment load pin transmits software version.
C PIN SN
Cylinder moment load pin transmits serial number.
ANALYZER
VX.XXXX
Analyzer software version
Table 6-6. Machine Diagnostics Parameters
Diagnostics
Submenu
(Displayed on
Analyzer 1
st
Line)
Parameter (Displayed
on Analyzer 2
nd
Line)
Parameter Value
(Displayed on Analyzer 2
nd
Line)