SECTION 6 - JLG CONTROL SYSTEM
6-52
– JLG Lift –
3121180
MOMENT:
Displayed if MODEL NUMBER = 7 or 8
(LB-IN) ACTUAL
XXXXXXXX
Current moment value
(LB-IN)
OVER
XXXXXXXX
Current over moment setpoint.
(LB-IN)
UNDER
XXXXXXXX
Current under moment setpoint.
CAL PT
UNDER
XXXXXXXX
Under moment value recorded during boom sensor calibration.
CAL PT
WIT YEL
XXXXXXXX
Yellow witness mark moment value recorded during boom sensor
calibration.
CAL PT
WIT GRN
XXXXXXXX
Green witness mark moment value recorded during boom sensor
calibration.
CYL PIN
RATIO
X.XXX
Current cylinder moment pin ratio of X and Y forces.
PIN
E FLAGS
0xXXXX
Current error flag status of cylinder moment pin.
sky welder
YES/NO
Status of Sky Welder selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)
sky cutter
YES/NO
Status of Sky Cutter selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)
sky glazier
YES/NO
Status of Sky Glazier selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)
sky Bright
YES/NO
Status of Sky Bright selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)
Pipe Racks
YES/NO
Status of Pipe Racks selected during boom sensor calibration.
(Displayed if MODEL NUMBER = 7 or 8)
Camera mount
YES/NO
Status of Camera Mount selected during boom sensor calibra-
tion. (Displayed if MODEL NUMBER = 7 or 8)
Table 6-6. Machine Diagnostics Parameters
Diagnostics
Submenu
(Displayed on
Analyzer 1
st
Line)
Parameter (Displayed
on Analyzer 2
nd
Line)
Parameter Value
(Displayed on Analyzer 2
nd
Line)
Description