SECTION 6 - JLG CONTROL SYSTEM
3121623
– JLG Lift –
6-81
BMS fault codes
In any case, when the display shows a fault code of the
BMS, we suggest to connect Rahmino software to the
machine.
EXAMPLES OF BMS ERROR
02 – UNEXPECTED VOLTAGE:
In case of one cell reach 3650 mV the BMS will disconnect
the lithium pack and the system will show the “UNEX-
PECTED VOLTAGE” error. This could be caused by a fail-
ure on BMS that doesn’t recognize one cell or cannot
connect it to the discharging resistance.
05 - OVERCURRENT CHARGE:
While the lithium pack is warm and one cell is already at
the maximum value, when the battery charger is suddenly
connected for a while one impulse of current will feed the
pack, in this case could happen that the system will show
the “OVERCURRENT CHARGE” error.
Table 6-12.
CODE
MEANING
01
SYSTEM CONFIGURATION ERROR
02
UNEXPECTED VOLTAGE
03
UNEXPECTED TEMPERATURE
04
OVERCURRENT DISCHARGE
05
OVERCURRENT CHARGE
06
PRE-CHARGE ERROR
07
NO 12 VOLT SUPPLY
08
NO -12 VOLT SUPPLY
09
BATTERY OVERTEMPERATURE
10
ELECTRONICS OVERTEMPERATURE
11
BAD TEMP SENSOR AUTO SHUT OFF
MODE
12
ALL TEMP SENSOR BROKEN
13
BROKEN TEMPERATURE SENSOR
DETECTED
14
GRUNDING FAULT ERROR
15
NO BOOTLOADER ERROR
16
SECOND PROTECTION
17
WATCHDOG ERROR
18
POWER BOARD ALARM
19
I2C MODULE NOT READY
20
I2C TX ERROR
21
I2C RX ERROR
22
I2C RX ERROR 2
23
AD ERROR
99
GENERAL ERROR