SECTION 6 - JLG CONTROL SYSTEM
6-32
– JLG Lift –
3121623
POSM3 B
ON
Do not consider
OFF
Do not consider
POSM4 A
ON
Do not consider
OFF
Do not consider
POSM4 B
ON
Do not consider
OFF
Do not consider
R.C. BASKET
ON
The remote control is in the support in basket
OFF
The remote control is not in the support in basket
INCLIN. X
0
Indicates the inclination of the machine on the X axis in tenth of degrees
(accelerometer A)
0
Indicates the inclination of the machine on the X axis in tenth of degrees (accel B)
INCLIN. Y
0
Indicates the inclination of the machine on the Y axis in tenth of degrees (accelerom-
eter A)
0
Indicates the inclination of the machine on the Y axis in tenth of degrees (accel B)
LOAD
94
Indicates the weight in Kg in the basket
POS. 1E2
0
Do not consider
POS. 3
2398
Indicates the opening of the 3 arm cylinder in tenths of a millimetre
ROTATION A
180
Do not consider
MOTOR RPM Diesel
Only
2200
Indicate the engine RPM
CURRENT A
2,5
Indicates (in tenth of mA) the current ECM1-2 is sending to the aerial part
proportional valve or to the left-side undercarriage proportional valve (values less
that 5 not relevant)
CURRENT B
45,3
Indicates (in tenth of mA) the current ECM1-2 is sending to the right-side
undercarriage proportional valve (values less that 5 not relevant)
CURRENT C
0
Do not consider
TEMPERAT.
37,6
Indicates the temperature of the control module in C°
SUPPLY (V)
12,1
Indicates the batteries voltage, or the output voltage from the battery charger
BATTERY %
100
Only for Lithium version: indicates the % level of charge of the pack