JLG X20JP - X600AJ Service Manual User Manual
Page 247

SECTION 6 - JLG CONTROL SYSTEM
3121623
– JLG Lift –
6-31
MOTOR PRES
To consider only for X20JP
- X600 AJ
ON
The engine oil pressure is inadequate (emergency condition – engine turns off)
OFF
The engine oil pressure is OK
START M.EL
ON
The ground button for electric motor start is pressed
OFF
The ground button for electric motor start is released
GND/BASKET
ON
The control position key selector is positioned on “basket”
OFF
The control position key selector is positioned on “ground”
MICROJIB A
ON
The JIB is closed – the control switch is released and “A” line is closed
OFF
The JIB is open – the control switch is pressed and “A” line is open
MICROJIB B
ON
The JIB is closed – the control switch is released and “B” line is closed
OFF
The JIB is open – the control switch is pressed and “B” line is open
PEDAL
ON
The pedal is pressed– the pedal electric line is closed
OFF
The pedal is released – the pedal electric line is open
FREE B
Do not consider this signal
EM.BASK.A
ON
The stop button on remote control in basket is released – “A” line is closed
OFF
The stop button on remote control in basket is pressed or the ground remote
control is disconnected – “A” line is open
EM.BASK. B
ON
The stop button on remote control in basket is released – “B” line is closed
OFF
The stop button on remote control in basket is pressed or the ground remote
control is disconnected – “B” line is open
POSM1 A
ON
Do not consider
OFF
Do not consider
POSM1 B
ON
Do not consider
OFF
Do not consider
POSM2 A
ON
Do not consider
OFF
Do not consider
POSM2 B
ON
Do not consider
OFF
Do not consider
POSM3 A
ON
Do not consider
OFF
Do not consider
X17JP - X20JP - X500AJ - X600AJ