beautypg.com

3 traction system, Theory of operation, Traction system -3 – JLG 3246ES Service Manual User Manual

Page 39: Theory of operation -3

background image

SECTION 3 - CHASSIS & SCISSOR ARMS

3121166

– JLG Lift –

3-3

3.3

TRACTION SYSTEM

Theory of Operation

The Armatures (rotating windings) of the separately-
excited drive motors are wired in parallel to the Power
Module's M1 and M2 terminals (Sevcon) and -T and +B
terminals (ZAPI) . The M1/+B Terminal is always at the
same voltage as the +B (Battery Voltage when the Line
Contactor is closed) and allows the module to measure
current with the internal shunt (extremely low imped-
ance). The M2/-T Terminal is pulled to Ground by the
Armature Switch MOSFET's (connected to -B Terminal).

To provide variable speed control, the Armature MOS-
FET transistors switch On and Off at high frequencies
(pulse-width modulation; 16kHz). The Duty Cycle (On &
Off time) is varied to control the voltage applied to the
Armatures. When the MOSFET's spend 50% of the
period On and 50% Off, approximately ½ of the avail-
able Battery Voltage will be applied to the Armatures.
Similarly, the MOSFET are On continuously (100% Duty
Cycle) to apply all available Battery Voltage to the Arma-
tures (as in Driving at Full Speed).

Instead of permanent magnets, the separately-excited
drive motors use electro-magnets (called Field Wind-
ings) located in the stator (non-rotating) portion of the
motor. Field windings are preferable to permanent
magnets because the Power Module can adjust the sta-
tor's magnetism for optimum motor performance.
When climbing a grade a low speeds, the Power Module
may apply as much as 40A to the field windings for
more electro-motive force. On level terrain, the Power
Module will apply as little as 14A to the fields for higher
rotational speeds and better electrical efficiency.

The Field Windings also provide direction reversal for
traction. When driving forward, MOSFET switches 1 and
4 turn On to apply positive potential to F2 and ground
potential to F1. In reverse, MOSFET switches 2 and 3
turn On to apply positive potential to F1 and ground
potential to F2. Theses switches are pulse-width modu-
lated by the Power Module to maintain a fixed relation-
ship between Field and Armature Current (also called
the Field Map).

Since the two 24V Armatures are wired in parallel, the
drive motors will attempt to rotate at the same speed
under all conditions. If one wheel slips, the wheel with
traction will demand more current as it slows slightly
(under load). In this manner, the system provides effec-
tive traction control with no added complexity.

It is essential that the same amount of field current is
supplied to both drive motors, or one wheel will pull the
vehicle (motor overheating and excessive tire wear
would result). Independent field control would require a
more complex Power Module, and parallel field wind-
ings would require impedance matching. For simplicity,
the vehicle uses 12V field windings wired in series to
ensure proper distribution of current.

Two electrically-released parking brakes are mounted to
the rear of the drive motors. The Ground Module ener-
gizes the two 24V electro-magnets when appropriate to
allow vehicle motion. The parking brakes can be
released electrically for emergency vehicle towing