beautypg.com

JLG 3246ES Service Manual User Manual

Page 141

background image

SECTION 5 - JLG CONTROL SYSTEM

3121166

– JLG Lift –

5-21

9 9

FUNCTIONS LOCKED OUT – MACHINE NOT CONFIGURED

The control system has not been configured for the first time.
9-9 Flash Code
The control system’s EEPROM flag indicates that the vehicle has
not been configured (new control system components).
Retained until EEPROM flag is cleared and power is re-cycled.

Use the JLG Analyzer to adjust all
Machine Setup and Personality
settings and re-cycle power to
clear difficulty.

9 9

FUNCTIONS LOCKED OUT – PLATFORM MODULE SOFT-
WARE VERSION IMPROPER

The control system will not function because the Platform
Module Software Version is not compatible with the rest of the
system.
9-9 Flash Code
The Platform Module reported a Software Major Version that
was not equal to “1”. The control system may resume operation
once the difficulty has been corrected.

Re-program or replace with a
Version 1.xx module.

9 9

FUNCTIONS LOCKED OUT – POWER MODULE SOFTWARE
VERSION IMPROPER

The control system will not function because the Power Mod-
ule Software Version is not compatible with the rest of the sys-
tem.
9-9 Flash Code
The Power Module reported a Software Major Version that was
not equal to “1”. The control system may resume operation
once the difficulty has been corrected.

Re-program or replace with a
Version 1.xx module.

9 9

FUNCTIONS LOCKED OUT – LSS MODULE SOFTWARE
VERSION IMPROPER

The control system will not function because the LSS Module
Software Version is not compatible with the rest of the system.
9-9 Flash Code
Machine Setup’s LOAD=1 or 2 AND the LSS Module reported a
Software Major Version that was not equal to “7”. The control
system may resume operation once the difficulty has been cor-
rected.

Re-program or replace with a
Version 7.xx module.

Table 5-2. Flash Code Listing

Flash

Code

Help Message

Cause

Possible Resolve