SECTION 5 - JLG CONTROL SYSTEM
3121166
– JLG Lift –
5-21
9 9
FUNCTIONS LOCKED OUT – MACHINE NOT CONFIGURED
The control system has not been configured for the first time.
9-9 Flash Code
The control system’s EEPROM flag indicates that the vehicle has
not been configured (new control system components).
Retained until EEPROM flag is cleared and power is re-cycled.
Use the JLG Analyzer to adjust all
Machine Setup and Personality
settings and re-cycle power to
clear difficulty.
9 9
FUNCTIONS LOCKED OUT – PLATFORM MODULE SOFT-
WARE VERSION IMPROPER
The control system will not function because the Platform
Module Software Version is not compatible with the rest of the
system.
9-9 Flash Code
The Platform Module reported a Software Major Version that
was not equal to “1”. The control system may resume operation
once the difficulty has been corrected.
Re-program or replace with a
Version 1.xx module.
9 9
FUNCTIONS LOCKED OUT – POWER MODULE SOFTWARE
VERSION IMPROPER
The control system will not function because the Power Mod-
ule Software Version is not compatible with the rest of the sys-
tem.
9-9 Flash Code
The Power Module reported a Software Major Version that was
not equal to “1”. The control system may resume operation
once the difficulty has been corrected.
Re-program or replace with a
Version 1.xx module.
9 9
FUNCTIONS LOCKED OUT – LSS MODULE SOFTWARE
VERSION IMPROPER
The control system will not function because the LSS Module
Software Version is not compatible with the rest of the system.
9-9 Flash Code
Machine Setup’s LOAD=1 or 2 AND the LSS Module reported a
Software Major Version that was not equal to “7”. The control
system may resume operation once the difficulty has been cor-
rected.
Re-program or replace with a
Version 7.xx module.
Table 5-2. Flash Code Listing
Flash
Code
Help Message
Cause
Possible Resolve