8 2
LSS CELL #2 ERROR
Cell #2’s Bridge <2Vdc, >3Vdc, or could the LSS Module could
not read Cell #2’s Internal Memory.
8-2 Flash Code
LSS Module Message – Status Message (0x81) is reporting
“CELL 2 ERROR” AND [Machine Setup’s LOAD is set to 1=CUT-
OUT PLT OR 2=CUTOUT ALL].
Vehicle assumed to be Overloaded.
This situation indicates that the
sensor is unplugged, or the sen-
sor is damaged.
8 3
LSS CELL #3 ERROR
Cell #3’s Bridge <2Vdc, >3Vdc, or could the LSS Module could
not read Cell #3’s Internal Memory.
8-3 Flash Code
LSS Module Message – Status Message (0x81) is reporting
“CELL 3 ERROR” AND [Machine Setup’s LOAD is set to 1=CUT-
OUT PLT OR 2=CUTOUT ALL].
Vehicle assumed to be Overloaded.
This situation indicates that the
sensor is unplugged, or the sen-
sor is damaged.
8 4
LSS CELL #4 ERROR
Cell #4’s Bridge <2Vdc, >3Vdc, or could the LSS Module could
not read Cell #4’s Internal Memory.
8-4 Flash Code
LSS Module Message – Status Message (0x81) is reporting
“CELL 4 ERROR” AND [Machine Setup’s LOAD is set to 1=CUT-
OUT PLT OR 2=CUTOUT ALL].
Vehicle assumed to be Overloaded.
This situation indicates that the
sensor is unplugged, or the sen-
sor is damaged.
Help messages with the 9-x flash codes indicate controller (module) problems. The second digit of the flash code provides additional information
about the difficulty.
9 1
LSS WATCHDOG RESET
The Watchdog Timer on Load Sensing System Module’s micro-
processor was triggered by exposure to excessive electrical
noise, or by a hardware difficulty.
9-1 Flash Code
LSS Module Message – Status Message (0x81) is reporting
“WATCHDOG RST” AND [Machine Setup’s LOAD is set to 1=CUT-
OUT PLT OR 2=CUTOUT ALL]. Retained until power is re-
cycled.
No motion interlocks.
Re-cycle power to clear diffi-
culty
9 2
LSS EEPROM ERROR
Memory used to retain settings on Load Sensing System Mod-
ule has been corrupted and must be reset by verifying all
entries / re-calibrating.
9-2 Flash Code
LSS Module Message – Status Message (0x81) is reporting
“EEPROM ERROR” AND [Machine Setup’s LOAD is set to 1=CUT-
OUT PLT OR 2=CUTOUT ALL]. Retained until power is re-cycled.
Vehicle assumed to be Overloaded
After resolution, re-cycle power
to clear difficulty.
9 3
LSS HAS NOT BEEN CALIBRATED
9-3 Flash Code
The Load Sensing System’s Calibration EEPROM for Empty Plat-
form Load is set to Never Set (signature implanted by the In-
Circuit Test Fixture) AND [Machine Setup’s LOAD is set to
1=CUTOUT PLT OR 2=CUTOUT ALL]. Retained until Calibration
EEPROM is over-written by a valid calibration.
Vehicle assumed to be Overloaded.
Calibrate the Load Sensing Sys-
tem using the calibration proce-
dure to clear the message.
Table 5-2. Flash Code Listing
Flash
Code
Help Message
Cause
Possible Resolve