009
DRIVE PREVENTED - ELE-
VATED ABOVE DRIVE
CUTOUT HEIGHT
The platform is elevated above
the calibrated cutout height.
• Check that the elevation angle sensor is securely
mounted.
• Check the ANALYZER -> MACHINE SETUP -> MARKET
configuration.
• If MARKET is set to Japan, ensure ANALYZER ->
MACHINE SETUP -> DRIVE CUTOUT parameter is set as
desired.
2-1 Power-Up
DTC
FAULT MESSAGE
DESCRIPTION
CHECK
211
POWER CYCLE
This help message is issued at
each power cycle. Displays on
the analyzer only.
Normal operation. No check necessary.
212
KEYSWITCH FAULTY
Both platform and ground
modes are selected simultane-
ously. Defaults to ground mode.
• Check key switch function.
• Backprobe J2-3 with the keyswitch in the ground
position. Voltage should be under 6V. Otherwise, key-
switch or wiring faulty.
• Backprobe J2-4 with the keyswitch in the platform
position. Voltage should be under 6V. Otherwise, key-
switch or wiring faulty.
• Check key switch wiring to ground board J2-3 and J2-
4 and to emergency stop switch.
• Replace ground board.
2-2 Platform Controls
DTC
FAULT MESSAGE
DESCRIPTION
CHECK
221
FUNCTION PROBLEM -
HORN PERMANENTLY
SELECTED
The horn switch was closed dur-
ing power-up in platform mode.
• Check if the horn switch is damaged, obstructed or
jammed.
• Disconnect the horn switch ribbon cable on the plat-
form board. If DTC still present, replace the platform
board. If DTC 221 is no longer present, replace the
horn switch or platform board.
222
FUNCTION PROBLEM -
INDOOR / OUTDOOR
PERMANENTLY
SELECTED
The indoor / outdoor (zone A /
zone B) switch was closed dur-
ing power-up in platform mode.
• Check if the indoor/outdoor (zone A / zone B) capacity
switch is damaged, obstructed or jammed.
• Replace platform board.
223
FUNCTION PROBLEM -
DRIVE & LIFT ACTIVE
TOGETHER
The drive and lift inputs are
closed simultaneously in plat-
form mode.
• Check drive/lift switch for visible damage.
• Check switch continuity. There should only be conti-
nuity from the center post to one of the outer posts at
a time. Otherwise, replace the switch.
• Check drive/lift switch signal and wiring to the plat-
form board. Its input (0V) is from platform board ter-
minal J1-11. "Lift" selection output (0V when selected)
is to platform board terminal J1-9. "Drive" selection
output (0V when closed) is to platform board terminal
J1-10.
• Replace platform board.
0-0 Help Comments
DTC
FAULT MESSAGE
DESCRIPTION
CHECK