SECTION 6 - DIAGNOSTIC TROUBLE CODES

6-6

– JLG Lift –

3121166

009

DRIVE PREVENTED - ELE-
VATED ABOVE DRIVE
CUTOUT HEIGHT

The platform is elevated above
the calibrated cutout height.

• Check that the elevation angle sensor is securely

mounted.

• Check the ANALYZER -> MACHINE SETUP -> MARKET

configuration.

• If MARKET is set to Japan, ensure ANALYZER ->

MACHINE SETUP -> DRIVE CUTOUT parameter is set as
desired.

2-1 Power-Up

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

211

POWER CYCLE

This help message is issued at
each power cycle. Displays on
the analyzer only.

Normal operation. No check necessary.

212

KEYSWITCH FAULTY

Both platform and ground
modes are selected simultane-
ously. Defaults to ground mode.

• Check key switch function.
• Backprobe J2-3 with the keyswitch in the ground

position. Voltage should be under 6V. Otherwise, key-
switch or wiring faulty.

• Backprobe J2-4 with the keyswitch in the platform

position. Voltage should be under 6V. Otherwise, key-
switch or wiring faulty.

• Check key switch wiring to ground board J2-3 and J2-

4 and to emergency stop switch.

• Replace ground board.

2-2 Platform Controls

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

221

FUNCTION PROBLEM -
HORN PERMANENTLY
SELECTED

The horn switch was closed dur-
ing power-up in platform mode.

• Check if the horn switch is damaged, obstructed or

jammed.

• Disconnect the horn switch ribbon cable on the plat-

form board. If DTC still present, replace the platform
board. If DTC 221 is no longer present, replace the
horn switch or platform board.

222

FUNCTION PROBLEM -
INDOOR / OUTDOOR
PERMANENTLY
SELECTED

The indoor / outdoor (zone A /
zone B) switch was closed dur-
ing power-up in platform mode.

• Check if the indoor/outdoor (zone A / zone B) capacity

switch is damaged, obstructed or jammed.

• Replace platform board.

223

FUNCTION PROBLEM -
DRIVE & LIFT ACTIVE
TOGETHER

The drive and lift inputs are
closed simultaneously in plat-
form mode.

• Check drive/lift switch for visible damage.
• Check switch continuity. There should only be conti-

nuity from the center post to one of the outer posts at
a time. Otherwise, replace the switch.

• Check drive/lift switch signal and wiring to the plat-

form board. Its input (0V) is from platform board ter-
minal J1-11. "Lift" selection output (0V when selected)
is to platform board terminal J1-9. "Drive" selection
output (0V when closed) is to platform board terminal
J1-10.

• Replace platform board.

0-0 Help Comments

DTC

FAULT MESSAGE

DESCRIPTION

CHECK