SECTION 6 - DIAGNOSTIC TROUBLE CODES

6-20

– JLG Lift –

3121166

824

LSS CELL #4 ERROR

A problem has been detected
with the load sense system.

• Refer to Section 2.3: Troubleshooting in the LSS man-

ual, 3124288.

825

LSS HAS NOT BEEN CAL-
IBRATED

The load sensing system mod-
ule has not been calibrated

• Empty platform. Calibrate LSS, see Section 2.2: Cali-

bration in the LSS manual, 3124288.

• Refer to Section 2.3: Troubleshooting in the LSS man-

ual, 3124288.

9-9 Hardware

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

991

LSS WATCHDOG RESET

A problem has been detected
with the load sense system.

• Refer to Section 2.3: Troubleshooting in the LSS man-

ual, 3124288.

992

LSS EEPROM ERROR

A problem has been detected
with the load sense system.

• Refer to Section 2.3: Troubleshooting in the LSS man-

ual, 3124288.

993

LSS INTERNAL ERROR -
PIN EXCITATION

A problem has been detected
with the load sense system.

• Refer to Section 2.3: Troubleshooting in the LSS man-

ual, 3124288.

994

LSS INTERNAL ERROR -
DRDY MISSING FROM A/
D

A problem has been detected
with the load sense system.

• Refer to Section 2.3: Troubleshooting in the LSS man-

ual, 3124288.

995

POWER MODULE FAIL-
URE - PERSONALITY
RANGE ERROR

The power module detected an
out-of-range or corrupt person-
ality setting

• Record all personality settings in ANALYZER -> PER-

SONALITIES and ANALYZER -> MACHINE SETUP. Reset
control system personalities to default settings by
selecting a different model than indicated, cycle
power then select proper model. Then, enter person-
ality settings recorded above.

996

POWER MODULE FAIL-
URE - INTERNAL ERROR

Drive, Steer, & Lift Prevented

• The System Module’s analog to digital converter does

not respond for the power PCB. This is an internal fail-
ure.

• Cycle machine, if error still exists, replace System

Module.

• ZAPI - HEALTH (Status LED) - FLASHING

997

POWER MODULE FAIL-
URE - CHECK POWER
CIRCUITS OR MOSFET
SHORT CIRCUIT

The power module detected an
error in the power wiring for the
drive or pump.

• Refer to Drive Motor Electrical Evaluation in Section

3.5.

• Refer to Pump Motor Electrical Evaluation in Section

4.8.

• Refer to Power Module Electrical Evaluation in Sec-

tion 3.6.

998

EEPROM FAILURE -
CHECK ALL SETTINGS

The control system detected an
EEPROM failure.

• Replace ground board.

999

FUNCTION LOCKED
OUT - POWER MODULE
SOFTWARE VERSION
IMPROPER

The power module software ver-
sion is not compatible with the
rest of the system.

• Replace power module to clear fault.

9910 FUNCTION LOCKED

OUT - PLATFORM MOD-
ULE SOFTWARE VER-
SION IMPROPER

The platform board software
version is not compatible with
the rest of the system.

• Reprogram platform board.

8-2 Platform Load Sense

DTC

FAULT MESSAGE

DESCRIPTION

CHECK