Service - voltage reading, Service - voltage reading -9, Connector installation -9 – JLG 3246ES Service Manual User Manual
Page 185
SECTION 7 - GENERAL ELECTRICAL INFORMATION & SCHEMATICS
3121166
– JLG Lift –
7-9
Service - Voltage Reading
CAUTION
DO NOT PIERCE WIRE INSULATION TO TAKE VOLTAGE READINGS.
It has been common practice in electrical troubleshooting to probe wires by piercing the insulation with a sharp point.
This practice should be discouraged when dealing with the AMPSEAL plug assembly, or any other sealed connector sys-
tem. The resulting pinholes in the insulation will allow moisture to invade the system by traveling along the wire strands.
This nullifies the effectiveness of the connector seals and could result in system failure.
Figure 7-11. Connector Installation
This manual is related to the following products: