beautypg.com

Torque chart (metric fasteners - sheet 7 of 7) -15, Class 12.9 socket head cap screws m6 and above – JLG 3246ES Service Manual User Manual

Page 27

background image

SECTION 1 - SPECIFICATIONS

3121166

– JLG Lift –

1-15

Figure 1-7. Torque Chart (METRIC Fasteners - Sheet 7 of 7)

Size

PITCH

Tensile

Stress

Area

Clamp Load

See Note 4

Torque

(Dry or Loctite®

263

TM

)

K = .17

Torque

(Lub OR Loctite®

242

TM

or 271

TM

OR Vibra-TITE

TM

111 or 140)

K = .16

Torque

(Loctite® 262

TM

OR Vibra-TITE

TM

131)

K = .15

Sq mm

kN

[N.m]

[N.m]

[N.m]

3

0.5

5.03

3.5

0.6

6.78

4

0.7

8.78

5

0.8

14.20

6

1

20.10

12.5

13

12

11

7

1

28.90

18.0

21

20

19

8

1.25

36.60

22.8

31

29

27

10

1.5

58.00

36.1

61

58

54

12

1.75

84.30

52.5

105

100

95

14

2

115

71.6

170

160

150

16

2

157

97.8

265

250

235

18

2.5

192

119.5

365

345

325

20

2.5

245

152.5

520

490

460

22

2.5

303

189.0

705

665

625

24

3

353

220.0

900

845

790

27

3

459

286.0

1315

1235

1160

30

3.5

561

349.5

1780

1680

1575

33

3.5

694

432.5

2425

2285

2140

36

4

817

509.0

3115

2930

2750

42

4.5

1120

698.0

4985

4690

4395

CLASS 12.9 SOCKET HEAD CAP SCREWS

M6 AND ABOVE*

4. CLAMP LOAD LISTED FOR SHCS IS SAME AS GRADE 8 OR CLASS 10.9 AND DOES NOT
REPRESENT FULL STRENGTH CAPABILITY OF SHCS. IF HIGHER LOAD IS REQUIRED,
ADDITIONAL TESTING IS REQUIRED.

*3. ASSEMBLY USES HARDENED WASHER OR FASTENER IS PLACED AGAINST PLATED
STEEL OR RAW ALUMINUM

NOTES: 1. THESE TORQUE VALUES DO NOT APPLY TO CADMIUM PLATED FASTENERS

2. ALL TORQUE VALUES ARE STATIC TORQUE MEASURED PER STANDARD AUDIT
METHODS TOLERANCE = ±10%

NO. 5000059 REV. J

Magni Coating (Ref 4150701)*