SECTION 6 - DIAGNOSTIC TROUBLE CODES

3121166

– JLG Lift –

6-21

9911 FUNCTION LOCKED

OUT - LSS MODULE
SOFTWARE VERSION
IMPROPER

The load sensing system mod-
ule software version is not com-
patible with the rest of the
system.

• Replace LSS module to clear fault.

9912 POWER MODULE FAIL-

URE - SYSTEM MONITOR

The ground board detected
armature, field, or pump current
while function was not com-
manded.

• Refer to Drive Motor Electrical Evaluation in Section

3.5.

• Refer to Pump Motor Electrical Evaluation in Section

4.8.

• Refer to Power Module Electrical Evaluation in Sec-

tion 3.6.

9917 HIGH RESOLUTION

ANALOG TO DIGITAL
FAILURE - INTERRUPT
LOST

The ground board detected
armature, field, or pump current
while function was not com-
manded.

• Pump Motor being turned backwards by a faulty

check valve in the hydraulic system.

• Software issue on the controller. Update software.

9924 FUNCTIONS LOCKED

OUT - MACHINE NOT
CONFIGURED

The control system's memory
indicates that the vehicle has
not been configured (new con-
trol system components).

• Use the JLG analyzer to adjust all machine setup and

personality settings, refer to 5.7 Machine Configura-
tion Programming Information.

9950 POWER MODULE FAIL-

URE - INTERNAL ERROR

Drive, Steer, & Lift Prevented

• The System Module’s armature power circuitry is

driven without PWM command for 100mS.

• Cycle machine, if error still exists, replace System

Module.

• ZAPI - HEALTH (Status LED) - FLASHING

9951 POWER MODULE FAIL-

URE - INTERNAL ERROR

Drive, Steer, & Lift Prevented

• The System Module’s pump power circuitry is driven

without enable from the interface PCB for 100mS.

• Cycle machine, if error still exists, replace System

Module.

• ZAPI - HEALTH (Status LED) - FLASHING

9952 POWER MODULE FAIL-

URE - INTERNAL ERROR

Drive, Steer, & Lift Prevented

• The System Module’s pump power circuitry is driven

without PWM command for 100mS.

• Cycle machine, if error still exists, replace System

Module.

• ZAPI - HEALTH (Status LED) - FLASHING

9953 POWER MODULE FAIL-

URE - INTERNAL ERROR

Drive, Steer, & Lift Prevented

• The System Module’s field power circuitry is driven

without enable from the interface PCB for 100mS.

• Cycle machine, if error still exists, replace System

Module.

• ZAPI - HEALTH (Status LED) - FLASHING

9954 POWER MODULE FAIL-

URE - INTERNAL ERROR

Drive, Steer, & Lift Prevented

• The System Module’s field power circuitry is driven

without reverse direction from the power PCB for
100mS.

• Cycle machine, if error still exists, replace System

Module.

• ZAPI - HEALTH (Status LED) - FLASHING

9955 POWER MODULE FAIL-

URE - INTERNAL ERROR

Drive, Steer, & Lift Prevented

• The System Module’s field power circuitry is driven

without forward selection from the power PCB for
100mS.

• Cycle machine, if error still exists, replace System

Module.

• ZAPI - HEALTH (Status LED) - FLASHING