Step 3 — downflow applications, Condensate trap field drain attachment, Pressure switch tubing – Bryant Bruant 4 Way Gas 355AAV User Manual

Page 9: Upper inducer housing drain connection, Condensate trap freeze protection, 355a

background image

9

COLLECTOR BOX

TUBE (PINK)

COLLECTOR BOX

TUBE (GREEN)

INDUCER HOUSING

(MOLDED) DRAIN

TUBE (BEHIND

COLLECTOR BOX

DRAIN TUBE)

COLLECTOR BOX

DRAIN TUBE (BLUE)

FIELD-INSTALLED

FACTORY-SUPPLIED

DRAIN TUBE

COUPLING (LEFT

DRAIN OPTION)

FIELD-INSTALLED

FACTORY-SUPPLIED

DRAIN TUBE

FIELD-INSTALLED

FACTORY-SUPPLIED

DRAIN TUBE

COUPLING (RIGHT

DRAIN OPTION)

CAP

COLLECTOR BOX

DRAIN TUBE (BLUE

& WHITE STRIPED)

PLUG

FIELD-INSTALLED

FACTORY-SUPPLIED

1

Ú

2

-IN. CPVC STREET

ELBOWS (2) FOR

LEFT DRAIN OPTION

CONDENSATE

TRAP

A94213

Fig. 7 -- Factory--Shipped Upflow Tube Configuration

(Shown with Blower Access Panel Removed)

Condensate Trap Tubing (alternate Upflow Orienta-

tion)

NOTE: See Fig. 8 or tube routing label on main furnace door to
confirm location of these tubes.

1. Collector Box Drain Tube

Connect collector box drain tube (blue label) to condensate

trap.

NOTE: On 17--1/2--in. (445 mm) wide furnaces ONLY, cut tube
between corrugated sections to prevent kinks.

2. Inducer Housing Drain Tube

a. Remove and discard LOWER (molded) inducer housing

drain tube which was previously connected to
condensate trap.

b. Use inducer housing drain extension tube (violet label

and factory--supplied in loose parts bag) to connect
LOWER inducer housing drain connection to

condensate trap.

c. Determine appropriate length, then cut and connect

tube.

d. Clamp tube to prevent any condensate leakage.

3. Relief Port Tube

a. Connect relief port tube (green label) to condensate trap.

b. Extend this tube (if required) by splicing to small

diameter tube (factory--supplied in loose parts bag).

Condensate Trap Field Drain Attachment

Refer to Condensate Drain section for recommendations and
procedures.

COLLECTOR BOX

TUBE (PINK)

CONDENSATE

TRAP

COLLECTOR BOX

TUBE (GREEN)

COLLECTOR BOX

DRAIN TUBE (GREEN)

INDUCER

HOUSING

DRAIN TUBE

(VIOLET)

CAP

COLLECTOR BOX

DRAIN TUBE (BLUE

& WHITE STRIPED)

PLUG

A94214

Fig. 8 -- Alternate Upflow Tube Configuration and Trap

Location

Pressure Switch Tubing

The LOWER collector box pressure tube (pink label) is factory

connected to the pressure switch and should not require any
modification.
NOTE: See Fig. 7 or 8 or tube routing label on main furnace door
to check for proper connections.

Upper Collector Box and Inducer Housing (Unused)

Drain Connections
Upper Collector Box Drain Connection

Attached to the UPPER collector box drain connection is a

factory--installed corrugated, plugged tube (blue and white striped
label). This tube is plugged to prevent condensate leakage in this

application. Ensure this tube is plugged.
NOTE: See Fig. 7 or 8 or tube routing label on main furnace door
to check for proper connections.

Upper Inducer Housing Drain Connection

Attached to the UPPER (unused) inducer housing drain connection

is a cap and clamp. This cap is used to prevent condensate leakage
in this application. Ensure this connection is capped.
NOTE: See Fig. 7 or 8 or tube routing label on main furnace door
to check for proper connections.

Condensate Trap Freeze Protection

Refer to Condensate Drain Protection section for recommendations
and procedures.

Step 3 — Downflow Applications

A downflow furnace application is where furnace blower is located

above combustion and controls section of furnace, and conditioned
air is discharged downwards.

355A