beautypg.com

Caution, Attachment of combustion air pipe, 355a – Bryant Bruant 4 Way Gas 355AAV User Manual

Page 35

background image

35

24-V THERMOSTAT

TERMINALS

PL2 – HOT SURFACE

IGNITER & INDUCER

MOTOR CONNECTOR

115-VAC (L2) NEUTRAL

CONNECTIONS

115-VAC (L1) LINE

VOLTAGE CONNECTIONS

EAC-1 TERMINAL

(115 -VAC 1.0 AMP MAX.)

PL1 – LOW VOLTAGE MAIN

HARNESS CONNECTOR

PL3 – ECM BLOWER

HARNESS

CONNECTOR

TRANSFORMER 24-VAC

CONNECTIONS

3-AMP FUSE

STATUS AND COMM

LED LIGHTS

SW1 SETUP

SWITCHES AND

BLOWER OFF-

DELAY

MODEL PLUG

CONNECTOR

AIR CONDITIONING

(A/C) AIRFLOW

SETUP SWITCHES

USER INTERFACE

OR ADVANCED

PRODUCT

MONITOR

CONNECTOR

CONTINUOUS FAN

(CF) AIRFLOW

SETUP SWITCHES

OAT

CONNECTOR

HUMIDIFIER

TERMINAL (24-VAC

0.5 AMP MAX.

ACRDJ – AIR

CONDITIONING

RELAY DISABLE

JUMPER

FLASH

UPGRADE

CONNECTOR

(FACTORY

ONLY)

SW4 SETUP

SWITCHES

BOARD SERIAL

NUMBER

EXAMPLE:

V12 HK42FZ022 3407

SOFTWARE

VERSION

NUMBER

DATE

CODE

PART

NUMBER

A07422

Fig. 37 -- Control Center

A07898

Fig. 38 -- Combustion--Air and Vent Pipe Connections

UNIT MAY NOT OPERATE
Failure to follow this caution may result in incomplete

combustion, flame disturbance, or flame sense lockout.
When installing combustion air and vent system of short pipe

length, the smallest allowable pipe diameter must be used.

CAUTION

!

NOTE: A 2--in. (51 mm) diameter pipe must be used within
furnace casing. Make all pipe diameter transitions outside furnace
casing per Fig. 40.

2. Unless noted in Table 11, insert perforated disk assembly

(factory--supplied in loose parts bag) in intake housing

where combustion air pipe will be connected. If half disk set
is required, install only shouldered disk half.

Attachment of Combustion Air Pipe

1. Determine location of combustion air intake pipe

connection to combustion air intake housing as shown in

Fig. 38 for application.

2. Reposition combustion air intake housing plug fitting in

appropriate unused intake housing connection.

3. Install combustion--air pipe grommet (factory--supplied in

loose parts bag) into selected furnace casing combustion--air

pipe hole.

355A