CONDENSATE

TRAP

AUXILIARY "J" BOX

PLUG

CAP

INDUCER HOUSING
DRAIN TUBE (VIOLET)

COLLECTOR BOX
DRAIN TUBE (BLUE)

COLLECTOR BOX TUBE (PINK)

RELOCATE TUBE BETWEEN BLOWER SHELF AND INDUCER HOUSING FOR

060, AND 080 HEATING INPUT FURNACES

COLLECTOR BOX

EXTENSION TUBE

COLLECTOR BOX
DRAIN TUBE
(BLUE AND WHITE STRIPED)

DRAIN TUBE COUPLING

COLLECTOR BOX
TUBE (GREEN)

COLLECTOR

BOX EXTENSION

DRAIN TUBE

A02288

Fig. 11 -- Horizontal Left Tube Configuration

b. Remove and discard UPPER (molded) inducer housing

drain tube which was previously connected to

condensate trap.

c. Install cap and clamp on UPPER inducer housing drain

connection where molded drain tube was removed.

d. Use inducer housing drain tube (violet label and

factorysupplied in loose parts bag) to connect LOWER

inducer housing drain connection to the condensate trap.

e. Connect inducer housing drain connection to

condensate trap.

(1.) Condensate Trap Located on Left Side of Casing

a. Determine appropriate length and cut.

b. Connect tube to condensate trap.

c. Clamp tube to prevent any condensate leakage.

(2.) Condensate Trap Located on Right Side of Casing

a. Route inducer housing drain tube (violet label) directly

from inducer housing to condensate trap.

b. Determine appropriate length and cut.

c. Connect tube to condensate trap.

d. Clamp tube to prevent any condensate leakage.
3. Relief Port Tube

Refer to Pressure Switch Tubing section for connection pro-

cedure.

Condensate Trap Field Drain Attachment

Refer to Condensate Drain section for recommendations and

procedures.

Pressure Switch Tubing

One collector box pressure tube (pink label) is factory connected to
the pressure switch for use when furnace is installed in UPFLOW

or HORIZONTAL LEFT applications. This tube MUST be

disconnected and used for the condensate trap relief port tube. The
other collector box pressure tube (green label) which was factory

connected to the condensate trap relief port connection MUST be
connected to the pressure switch in DOWNFLOW or

HORIZONTAL RIGHT applications.
NOTE: See Fig. 9 or 10 or tube routing label on main furnace
door to check for proper connections.
Relocate tubes as described below.

1. Disconnect collector box pressure tube (pink label) attached

to pressure switch.

2. Extend collector box pressure tube (green label) which was

previously connected to condensate trap relief port

connection

by

splicing

to

small

diameter

tube

(factory--supplied in loose parts bag).

3. Connect collector box pressure tube (green label) to

pressure switch connection labeled COLLECTOR BOX.

4. Extend collector box pressure tube (pink label) which was

previously connected to pressure switch by splicing to
remaining small diameter tube (factory--supplied in loose
parts bag).

5. Route this extended tube (pink label) to condensate trap

relief port connection.

6. Determine appropriate length, cut, and connect tube.
7. Clamp tube to relief port connection.

355A