Condensate Trap Location

The condensate trap must be removed from the factory--installed

blower shelf location and relocated in selected application location
as shown in Fig. 2, 9, or 10.
To relocate condensate trap from the blower shelf to desired
location, perform the following:

1. Remove 3 tubes connected to condensate trap.
2. Remove trap from blower shelf by gently pushing tabs in-

ward and rotating trap.

3. Remove casing hole filler cap from casing hole. (See Fig. 2

and 10.)

4. Install casing hole filler cap (factory--supplied in loose parts

bag) into blower shelf hole where trap was removed.

CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in personal injury

or death.
Casing hole filler cap must be installed in blower shelf hole

when condensate trap is relocated to prevent combustion

products being drawn in from appliances in the equipment

room

!

WARNING

5. Install condensate trap into left--hand side casing hole by

inserting tube connection stubs through casing hole and
rotating until tabs snap into locking position.

6. Fill unused condensate trap casing holes with plastic filler

caps (factory--supplied in loose parts bag).

PLUG

COLLECTOR BOX
TUBE (GREEN)

COLLECTOR BOX
TUBE (PINK)

COLLECTOR BOX
DRAIN TUBE (BLUE
& WHITE STRIPED)

COLLECTOR BOX
EXTENSION
DRAIN TUBE

CONDENSATE
TRAP

INDUCER HOUSING
DRAIN TUBE
(VIOLET)

COLLECTOR BOX
EXTENSION TUBE

DRAIN TUBE
COUPLING

COLLECTOR BOX
DRAIN TUBE (BLUE)

CAP

A94216

Fig. 10 -- Downflow Tube Configuration

(Right--Hand Trap Installation)

Condensate Trap Tubing

NOTE: See Fig. 9 or 10 or tube routing label on main furnace
door to check for proper connections.

1. Collector Box Drain Tube

a. Remove factory--installed plug from LOWER collector

box drain tube (blue and white striped label).

b. Install removed clamp and plug into UPPER collector

box drain tube (blue label) which was connected to

condensate trap.

c. Connect LOWER collector box drain connection to

condensate trap.

S

Condensate Trap Located on Left Side of Casing

a. Connect LOWER collector box drain tube (blue and white

striped label) to condensate trap. Tube does not need to be

cut.

b. Clamp tube to prevent any condensate leakage.

S

Condensate Trap Located on Right Side of Casing

a. Install drain tube coupling (factory--supplied in loose parts

bag) into collector box drain tube (blue and white striped

label) which was previously plugged.

b. Connect larger diameter drain tube (factorysupplied in loose

parts bag) to drain tube coupling, extending collector box

drain tube for connection to condensate trap.

c. Route extended collector box drain tube between gas valve

and inlet housing as shown in Fig. 10.

d. Determine appropriate length and cut.

e. Connect to condensate trap.

f. Clamp tube to prevent any condensate leakage.

2. Inducer Housing Drain Tube

a. Remove factory--installed cap and clamp from LOWER

inducer housing drain connection.

355A