beautypg.com

Bryant 330JAV User Manual

Service and maintenance procedures, Re g ist ered f ir m

background image

NOTE:

Read the entire instruction manual before starting the

installation.
This symbol

indicates a change since the last issue.

TABLE OF CONTENTS

SAFETY CONSIDERATIONS .....................................................1
INTRODUCTION ..........................................................................2
ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS
PROCEDURE ................................................................................2
CARE AND MAINTENANCE.....................................................2

Cleaning and/or Replacing Air Filter.......................................2
Blower Motor and Wheel.........................................................3
Cleaning Heat Exchanger .........................................................4
Electrical Controls and Wiring.................................................6

WIRING DIAGRAMS...................................................................7
TROUBLESHOOTING .................................................................7

SAFETY CONSIDERATIONS

Installing and servicing heating equipment can be hazardous due to
gas and electrical components. Only trained and qualified person-
nel should install, repair, or service heating equipment.
Untrained personnel can perform basic maintenance functions
such as cleaning and replacing air filters. All other operations must
be performed by trained service personnel. When working on
heating equipment, observe precautions in the literature, tags, and
labels attached to or shipped with the unit and other safety
precautions that may apply.

Follow all safety codes. In the United States, follow all safety
codes including the National Fuel Gas Code (NFGC) NFPA No.
54-1999/ANSI Z223.1-1999. In Canada, refer to the current
edition of the National Standard of Canada CAN/CGA-B149.1-
and .2-M00 Natural Gas and Propane Gas Installation Codes
(NSCNGPIC) and Amendment No. 1. Wear safety glasses and
work gloves. Have fire extinguisher available during start-up and
adjustment procedures and service calls.

REGISTERED QUALITY SYSTEM

C

ar

rie

r Corporat

io

n

R

E

G

IST

ERED F

IR

M

IS

O

9001 #A28

83

®

EFFICIENCY

RATING

CERTIFIED

CERTIFIED

Fig. 1—Model 330JAV Horizontal

A95137

Fig. 2—Model 331JAV Downflow

A94086

Fig. 3—Model 330JAV Upflow

A94085

service and
maintenance procedures

PLUS 80 2-STAGE GAS-FIRED
INDUCED-COMBUSTION FURNACES

Cancels:

SP04-65

SP04-73

11-01

330JAV
331JAV

Series D

—1—

This manual is related to the following products: