355a – Bryant Bruant 4 Way Gas 355AAV User Manual

Page 23

background image

23

Table 3 –

Opening Dimensions --- In. (mm)

FURNACE

CASING

WIDTH

APPLICATION

PLENUM OPENING

FLOOR OPENING

A

B

C

D

17-1/2

(445)

Upflow Applications

16

(406)

24-1/8

(613)

16-5/8

(422)

24-3/4

(629)

Downflow Applications on Non-Combustible Flooring

15-7/8

(403)

19

(483)

16-1/2

(419)

19-5/8

(498)

Downflow Applications on Combustible Flooring Using KGASB Sub-

base Furnace with or without CAP, CAR, CNPV, CNRV Coil Assem-

bly or KCAKC Coil Box

15-1/8

(384)

19

(483)

16-3/4

(425)

20-3/8

(518)

Downflow Applications on Combustible Flooring NOT Using KGASB

Subbase Furnace with CAP, CAR, CNPV, CNRV Coil Assembly or

KCAKC Coil Box

15-1/2

(394)

19

(483)

16-1/2

(419)

20

(508)

21

(533)

Upflow Applications

19-1/2

(495)

24-1/8

(613)

20-1/8

(511)

24-3/4

(629)

Downflow Applications on Non-Combustible Flooring

19-3/8

(492)

19

(483)

20

(508)

19-5/8

(498)

Downflow Applications on Combustible Flooring Using KGASB Sub-

base Furnace with or without CAP, CAR, CNPV, CNRV Coil Assem-

bly or KCAKC Coil Box

18-5/8

(473)

19

(483)

20-1/4

(514)

20-3/8

(518)

Downflow Applications on Combustible Flooring NOT Using KGASB

Subbase Furnace with CAP, CAR, CNPV, CNRV Coil Assembly or

KCAKC Coil Box

19

(483)

19

(483)

20

(508)

20

(508)

24-1/2

(622)

Upflow Applications

23

(584)

24-1/8

(613)

23-5/8

(600)

24-3/4

(629)

Downflow Applications on Non-Combustible Flooring

22-7/8

(581)

19

(483)

23-1/2

(597)

19-5/8

(498)

Downflow Applications on Combustible Flooring Using KGASB Sub-

base Furnace with or without CAP, CAR, CNPV, CNRV Coil Assem-

bly or KCAKC Coil Box

22-1/8

(562)

19

(483)

23-3/4

(603)

20-3/8

(518)

Downflow Applications on Combustible Flooring NOT Using KGASB

Subbase Furnace with CAP, CAR, CNPV, CNRV Coil Assembly or

KCAKC Coil Box

22-1/2

(572)

19

(483)

23-1/2

(597)

20

(508)

NOTES:

ANGLE
IRON OR
EQUIVALENT

(B)

(A) ROD LOCATION

USING DIMPLE
LOCATORS
(SEE DIMENSIONAL
DWG FOR
LOCATIONS)

13

/

16

-IN. (21mm) MAX

ALTERNATE SUPPORT
LOCATION FROM BACK

ALTERNATE SUPPORT
LOCATION 4-IN. (102mm) MIN
8-IN. (203mm) MAX

3/8-IN. (10mm) ROD

(A)

(B)

(A)

(B)

(B)

(A)

1. A 1 In. (25mm) clearance minimum between
top of furnace and combustible material.

2. The entire length of furnace must be
supported when furnace is used in horizontal
position to ensure proper drainage.

3. For non-direct vent/1-pipe application,
bottom side combustion-air entry cannot be
used when furnace is installed with hangers
as shown.

(A) PREFERRED ROD LOCATION

(B) ALTERNATE ROD LOCATION

DRAIN

5

3

/4

″ (146mm)

3

/

8

-IN. HEX NUT

& WASHER (4)

REQD PER ROD

VENT

COMBUSTION-AIR PIPE
(DIRECT VENT/2-PIPE
APPLICATION,ALL SIZES)

COMBUSTION-AIR INTAKE
(NON-DIRECT VENT/1-PIPE
APPLICATION)

3-IN. MINIMUM CLEARANCE TO
COMBUSTION-AIR INTAKE IS REQUIRED
(NON-DIRECT VENT/1-PIPE
APPLICATION,)

A93304

Fig. 26 -- Crawlspace Horizontal Application for Direct Vent / 2--Pipe Installation (Sizes 040 through 140) and for Non--Direct Vent

/ 1--Pipe Installation (Sizes 040 through 120 Only)

355A