24

RETURN AIR CONNECTIONS

FIRE HAZARD
Failure to follow this warning could result in fire, personal

injury or death.
Never connect return--air ducts to the back of the furnace.

Return--air duct connections on furnace side(s) permitted in

upflow applications only.

!

WARNING

Upflow Furnaces

The return--air duct must be connected to bottom, sides (left or
right), or a combination of bottom and side(s) of main furnace

casing. Bypass humidifier may be attached into unused side return
air portion of the furnace casing. DO NOT connect any portion of

return--air duct to back of furnace casing.

Downflow and Horizontal Furnaces

The return--air duct must be connected to return--air opening
provided. DO NOT cut into casing sides or back to attach any

portion of return--air duct. Bypass humidifier connections should

be made at ductwork or coil casing sides exterior to furnace.

Step 5 — Filter Arrangement

FIRE, CARBON MONOXIDE AND POISONING

HAZARD
Failure to follow this warning could result in personal injury

or death.
Never operate unit without a filter or with filter access door

removed.

!

WARNING

The air filter arrangement will vary due to application, furnace
orientation, and filter type. The filter may be installed in an

external Filter/Media cabinet (if provided) or the furnace blower

compartment. Factory supplied washable filters are shipped in the
blower compartment.
If a factory--supplied external Filter/Media cabinet is provided,
instructions for its application, assembly, and installation are

packaged with the cabinet. The Filter/Media cabinet can be used

with the factory--supplied washable filter or a factory--specified
high--efficiency disposable filter (see cabinet instructions). If

installing the filter in the furnace blower compartment, determine
location for filter and relocate filter retaining wire, if necessary. See

Table 4 to determine correct filter size for desired filter location.
Table 4 indicates filter size, location, and quantity shipped with this

furnace. See Fig. 2 for location and size of bottom and side

return--air openings.

CUT HAZARD
Failure to follow this caution may result in personal injury.
Use care when cutting support rods in filters to protect against

flying pieces and sharp rod ends. Wear safety glasses, gloves,

and appropriate protective clothing.

CAUTION

!

UNIT MAY NOT OPERATE
Failure to follow this caution may result in intermittent unit

operation or performance satisfaction.
For airflow requirements above 1800 CFM, see Air Delivery

table in Product Data literature for specific use of single side

inlets. The use of both side inlets, a combination of 1 side and

the bottom, or the bottom only will ensure adequate return air

openings for airflow requirements above 1800 CFM.

CAUTION

!

NOTE: Side return--air openings can ONLY be used in UPFLOW
configurations. Install filter(s) as shown in Fig. 27.
For bottom return--air applications, filter may need to be cut to fit

some furnace widths. Install filter as shown in Fig. 28.

Table 4 – Filter Information

AIR FILTER LOCATED IN BLOWER COMPARTMENT

Furnace

Casing

Width

In. (mm)

Filter Size --- In. (mm)

Filter Type

Framed

Side Return*{

Bottom Return*

17---1/2

(445)

(1) 16 X 25 X 3/4

(406 X 635 X 19)

(1) 16 X 25 X 3/4

(406 X 635 X 19)

Washable

21

(533)

(1) 16 X 25 X 3/4

(406 X 635 X 19)

(1) 20 X 25 X 3/4

(508 X 635 X 19)

Washable

24---1/2

(622)

(1 or 2) 16 X 25

X 3/4

(406 X 635 X 19)

(1) 24 X 25 X 3/4

(609 X 635 X 19)

Washable

* Factory---provided with the furnace. Filters may be field modified by cut-

ting filter material and support rods (3) in filters. Alternate sizes can be

ordered from your distributor or dealer.
{

Upflow only. Alternate sizes and additional filters may be ordered from

your dealer.