Bryant 376B User Manual
376b
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
i nstallation, operatron,
and maintenance instructions
HIGH-EFFICIENCY
DOWNFLOW/HORIZONTAL
INDUCED-COMBUSTION FURNACE
Sizes
040 and 055
075 thrullS
DOWNFLOW (In Alcove or Closet)
Sides—Single-Wall Vent
0
Type-B1 Double-Wail Vent
0
0
Back
0
0
Top
1
Front*—Single-Wall Vent
6
6
Type-B1 Double-Wall Vent
3 “
3
Vent—Single-Wail
6
6
Type-BI Double Wall
1
HORIZONTAL (In Alcove)
SidesT
0
Back
0
0
Top—Single-Wall Vent
1
Type-B1 Double-Wall Vent
0
0
Front*
18
18
Vent—Single-Wall
6
6
Type-BI Double-Wail
1
1
HORIZONTAL (In Closet)
Sides!
1
1 .
Back
3
3
Top—Single-Wall Vent
2
2
Type-BI Double-Wall Vent
2
2
Front*—Single-Wall Vent
6
6
Type-BI Double-Wall Vent
3
3
Vent—Single-Wall
6
6
Type-BI Double-Wall
1
1
Cancels; 39376DP5-A
376B
Series A
Sizes 040
thrullS
40376DP5-B
9/1/85
NOTE:
Remove the Energy Guide tag from the furpace
when the installation is complete.
NOTE;
This is a highly specialized piece of equipment.
Before
beginning
the
installation,
READ
THESE
INSTRUCTIONS CAREFULLY AND COMPLETELY.
INTRODUCTION
Before installing the furnace, refer to “Procedure for
Induced-Combustion Gas-Fired Furnaces” (packaged with
the equipment) for information concerning combustion,
venting, piping, and other standard installation practices.
Further reference is made to the current edition of the
National Fuel Gas Code NFPA No. 54-1984/ANSI Z223.1-
1984.
The induced-combustion vent system of this furnace is
designed to operate at zero or negative pressure at the vent
connector outlet. This furnace, therefore, complies with the
National Fuel Gas Code (NFPA No. 54-1984/ANSI Z223.1-
1984), Part 7.14.3.b. This furnace is also hsted by A.G.A. for
use with the type B1 gas vent, as described in the National
Fuel Gas Code, Part 7.3.2.
Each furnace is shipped from the factory completely assem
bled with multispeed direct-drive blower and wired ready for
indoor heating installation. All sizes feature a blower con
trol center with easy-to-read low-voltage terminal strip to
ensure proper connections.
The output capacity and any representations of efficiency
for this product are based on standard Department of
Energy test procedures. The insteJled operation may vary,
depending on installation, weather, or other factors.
TABLE I—CLEARANCES (In Inches)
A83215
Figure 2—Horizontal
♦Provide a 30-in. service clearance in front of the furnace,
t Indicates supply or return sides when furnace is in the horizontal
position.
The design of the downflow/horizontal gas-fired furnace is
A.G.A. certified for natural and LP(propane) gas and for
installation on combustible fiooring (with optional fioor
base), in alcoves, attics, crawl spaces, basements, closets, or
utility rooms. The design of this furnace line is not A.G.A.
certified for installation in mobile homes, recreation vehi
cles, or outdoors.
BDP Company