MIDI Implementation

Seconds Count

xxyyyyyy

xx

Reserved (00)

yyyyyy

Seconds (0-59)

Minutes Count

xxyyyyyy

xx

Reserved (00)

yyyyyy

Minutes (0-59)

Hours Count

xyyzzzzz

x

Reserved (0)

yy

Time Code Type

*

The time code types defined by the MIDI specification correspond to the BR-1600CD
Sync parameter “MTC Type” as follows.

MIDI specification setting

“MTC Type” setting

0 = 24 Frames / Sec

24

1 = 25 Frames / Sec

25

2 = 30 Frames / Sec (Drop Frame)

29D

3 = 30 Frames / Sec (Non Drop Frame

29N or 30

zzzzz

Hours

Song Position Pointer

Status

2nd byte

3rd byte

F2H

mmH

nnH

mm, nn=Song position point:

00H 00H - 7FH 7FH

*

The current position is transmitted by the Song Position Pointer Message when the BR-
1600CD is stopped, or the locate operation has been performed, if the SYNC parameter
“Sync Generator” is set to “MIDI CLOCK.”

System Realtime Messages

Timing Clock

Status
F8H

*

Transmitted when “Sync Generator” is “MIDI CLOCK” in the SYNC parameter.

Start

Status
FAH

*

Transmitted when “Sync Generator” is “MIDI CLOCK” in the SYNC parameter.

Continue

Status
FBH

*

Transmitted when “Sync Generator” is “MIDI CLOCK” in the SYNC parameter.

Stop

Status
FCH

*

Transmitted when “Sync Generator” is “MIDI CLOCK” in the SYNC parameter.

Active Sensing

Status
FEH

*

This is transmitted at intervals of approximately 200 msec.

System Exclusive Messages

Universal System Exclusive Message

Identity Reply Message

*

Receiving Identity Request Message, the BR-1600CD send this message.

Status

Data byte

Status

F0H

7EH, dev, 06H, 02H, 41H, 71H, 01H

F7H

00H, 00H, 00H, 00H, 00H, 00H

Byte

Remarks

F0H

Exclusive status

7EH

ID number (Universal Non-realtime Message)

dev

Device ID (dev: 10H - 1FH)

06H

Sub ID#1 (General Information)

02H

Sub ID#2 (Identity Reply)

41H

ID number (Roland)

71H 01H

Device family code

00H 00H

Device family number code

00H 00H 00H 00H

Software revision level

F7H

EOX (End of Exclusive)

For instructions on setting the device ID, refer to “How to set the device ID:” (p. 289).

MIDI Machine Control Command

Status

Data byte

Status

F0H

7FH, Dev, 06H, aaH, ..., bbH

F7H

Byte

Remarks

F0H

Exclusive Status

7FH

Universal System Exclusive Realtime Header

Dev

Device ID (7FH)

06H

MMC command message

aaH

command

:

:

bbH

command

F7H

EOX (End of Exclusive)

STOP (MCS)

Status

Data byte

Status

F0H

7FH, Dev, 06H, 01H

F7H

Byte

Remarks

F0H

Exclusive status

7FH

Universal System Exclusive Realtime Header

Dev

Device ID (7FH)

06H

MMC command message

01H

STOP (MCS)

F7H

EOX (End of Exclusive)

*

If the transport switch [STOP] was pressed, the BR-1600CD transmits this message.

DEFERRED PLAY (MCS)

Status

Data byte

Status

F0H

7FH, Dev, 06H, 03H

F7H

Byte

Remarks

F0H

Exclusive status

7FH

Universal System Exclusive Realtime Header

Dev

Device ID (7FH)

06H

MMC command message

03H

DEFERRED PLAY (MCS)

F7H

EOX (End of Exclusive)

*

If the transport switch [PLAY] was pressed, the BR-1600CD transmits this message.

RECORD STROBE

Status

Data byte

Status

F0H

7FH, Dev, 06H, 06H

F7H

Byte

Remarks

F0H

Exclusive status

7FH

Universal System Exclusive Realtime Header

Dev

Device ID (7FH)

06H

MMC command message

06H

RECORD STROBE

F7H

EOX (End of Exclusive)

*

Transmitted when recording to the audio tracks begins.

BR-1600_R_e.book 292 ページ 2007年12月6日 木曜日 午前9時52分