Using the Configuration Menus
36
8.2.5 Config Menu—Interface Configuration
This option lets you activate or deactivate the IR (infrared) and Ethernet interfaces.
To activate or deactivate the IR or Ethernet interfaces:
1. Press MENU twice.
The following message is displayed:
start configuration menu
MENU to view setup ENT to change them
2. Press MENU until the following is displayed:
INTERFACE configuration
current:IR-ON Ethernet-ON
The current status of the IR and Ethernet interfaces is displayed.
3. Press ENT to select the Interface Submenu.
4. Select 1 to modify the status of the IR interface or 2 to modify that status of
the Ethernet interface (in this example, 2).
The following is displayed:
Ethernet interface setup
1:make it ACTIVE
2:turn it OFF
5. Press 1 to activate the interface or 2 to deactivate it.
6. Press TAKE to confirm the action.
The interface status is changed. After a few seconds the next option on the
Config Menu is displayed.
8.2.6 Config Menu—Interface Reply Configuration
This option lets you switch the Reply configuration on or off. Setting Reply to on
causes all interfaces that are set to on to accept and execute commands, and also to
reply. Setting Reply to off causes all interfaces that are set to on to accept and
execute commands, but not to reply.
To switch the Reply configuration on or off:
1. Press MENU twice.
The following message is displayed:
start configuration menu
MENU to view setup ENT to change them
2. Press MENU until the following is displayed:
interface REPLY configuration
current interface REPLY – ON
This indicates the current Reply configuration status.
3. Press ENT to enter the Reply Submenu.
The following is displayed:
interface REPLY configuration
1:turn REPLY ON
2:never REPLY