4 config menu—output port parameter setting, Config menu—output port parameter setting – Kramer Electronics VS-1616D User Manual
Page 38

KRAMER: SIMPLE CREATIVE TECHNOLOGY
Using the Configuration Menus
34
8.2.4 Config Menu—Output Port Parameter Setting
This option sets port specific parameters. Ports that show an X have no parameters
available to modify. Ports that show a 0 have parameters available to modify. The
parameters that are available, such as, audio balance, depend on the type of card
installed and whether the card is an input or an output card. Tables listing output
cards and their parameters can be found at the end of this section.
To set parameters for a port:
1. Press MENU twice.
The following message is displayed:
start configuration menu
MENU to view setup ENT to change them
2. Press MENU until a display similar to the following is shown:
OUT: 01 02 03 04 05 06 07 08 09 10 11
SET: X X X X O O O O X X X
X indicates that there are no modifiable parameters for the associated port and
0 indicates that there are modifiable parameters for the associated port.
3. Press TAKE to enter the list of ports.
The cursor flashes on a selected port.
4. Select the required port to modify using the left and right arrow buttons.
5. Press TAKE to enter the parameters list.
A message similar to the following is displayed with the relevant port number
in place of 06:
OUT: 06
SET: 36.Reset SubBoard
6. To select the next parameter press the right arrow button. (See the table at the
end of this section for available parameters.)
Or:
7. To enter the displayed parameter press TAKE.
The parameter options are displayed.
8. Select the required action or number using the keypad numbers and arrows.
9. Press TAKE to save the change.
10. Repeat from Step 6 to modify other parameters
11. Do one of the following:
Press BREAKAWAY to exit the Config Menu
Wait approximately 15 seconds for the operation to time out
Press MENU to exit to the parameter list