Configuring the interval timer, Figure 53: broadcast storm control window – Allied Telesis AT-S39 User Manual
Page 176
AT-S39 User’s Guide
176
Configuring the Interval Timer
To set the interval timer for the broadcast frame control feature, perform
the following procedure:
1. From the Main Menu, type 5 to select System Config Menu.
2. From the System Configuration Menu, type A to select Advanced
Configuration.
3. From the Advanced Configuration Menu, type 2 to select Broadcast
Timers Setup.
The Broadcast Storm Control window in Figure 53 is displayed.
Figure 53 Broadcast Storm Control Window
4. Type 1 or 2 and enter a value when prompted.
The interval timer for 10 Mbps and 100 Mbps ports is in
milliseconds and has a range of 10 to 120 milliseconds. The value
should be entered in increments of 10.
The interval timer for 1000 Mbps ports is in microseconds and has
a range of 100 to 120000 microseconds. The value should be
entered in increments of 100.
A value for an interval timer applies to all ports operating at the
corresponding speed.
Note
The 1000 Mbps speed applies only to GBIC modules in an
AT-8024GB switch and expansion modules in an AT-8016F Series
switch.
Allied Telesyn Ethernet Switch AT-8024
Login Session: Manager
Broadcast Storm Control
1 - Timer for 10/100 MB ports ..... 10 milli sec
2 - Timer for 1000 MB ports ....... 100 micro sec
S - Save Configuration Changes
R - Return to Previous Menu
Enter your selection?