Displaying version and module information – Allied Telesis AT-S29 User Manual
Page 26

Using the System Configuration Program
26
Displaying
Version and
Module
Information
Use the Switch Information screen to display hardware/firmware version
numbers for the main board and agent modules, as well as the power
status and modules plugged into the system.
Parameter
Description
System Description
System hardware description.
System Object ID
MIB II object identifier for switch’s network
management subsystem
(ATI: 207.1.4.42)
System Up Time
Length of time the current management agent
has been running. (Note that the first value is
1/100 seconds.)
System Name
1
1. Maximum string length is 99, but the screen only displays 45 characters. You can use the arrow keys to
browse the whole string.
Name assigned to the switch system.
Contact person for the system.
System Location
Specifies the area or location where the system
resides.
Screen Information: Unit 1
=================
Main Board
Hardware Version
:
V3.0
Firmware Version
:
1.11
Serial Number
:
00-30-84-9A-3B-80
Port Number
:
25
Internal Power Status
:
Active
Redundant Power Status
:
Inactive
Expansion Slot 1
:
1000Base-SX
Expansion Slot 2
:
Stacking
Agent Module
Hardware Version
:
V2.
0 (801 CPU)
POST ROM Version
:
1.10
Firmware Version
:
1.12
SNMP Agent
:
Master
Use