System menu – navigation and editing, System menu – details – Horner APG QX751 OCS User Manual
Page 42
CH.9
MAN0890-02-EN
August 20, 2009
Page 42 of 96
ECN # 979
9.2
System Menu – Navigation and Editing
As mentioned above, pressing the front panel SYSTEM key starts the System Menu. Then, either press
ESC to exit the System Menu, or use the
↓
and
↑
keys to select an item and press Enter to display the
item’s Sub-Menu.
A Sub-Menu generally shows a list of System Settings and their values. After opening a Sub-Menu, if any
of its System Settings are editable, the first System Setting that can be edited is highlighted. If desired,
the
↓
and
↑
keys can be used to select a different System Setting to be edited.
At this point, either press ESC to exit the Sub-Menu (returning to the Main Menu) or press Enter to edit
the highlighted System Setting. If Enter is pressed, the System Setting’s value will be highlighted,
indicating that it is ready to be modified.
When modifying a System Setting’s value, use either the arrow keys (
←
,
→
,
↓
,
↑
) or the numeric keys to
select a new value.
The arrow keys are used to edit System Settings that have just a few possible values. Each time the
arrow key is pressed, a new possible value is displayed. When the desired value appears, press the
Enter key to save it; otherwise, press the ESC key to cancel the edit.
The numeric keys are normally used to enter numeric System Settings. In addition, to edit a single
numeric digit, use the
←
or
→
key to select the digit and then either press a numeric key or use
↓
or
↑
to
modify the digit. In any case, after entering the new desired value, press the Enter key to save it;
otherwise, press the ESC key to cancel the edit.
9.3
System Menu – Details
The following sections describe each of the Sub-Menus in detail.
Set Network ID
The Network ID Sub-Menu only appears for QX751 models that have a BPxx attached. This Sub-Menu
displays two System Settings of which only Network ID is editable.
Network Ok?
Yes
= CsCAN connected to a CAN network and functioning
properly
No
= Not ready to communicate on CAN network
Network ID:
1 to 253
= This (QX751/BPxx) node’s CsCAN Network ID; must be
unique on network
Set Network Baud
The Network Baud Sub-Menu only appears for QX751 models that have a BPxx attached. This Sub-
Menu displays just one System Setting and it is editable.
Network Baud:
125 KB
= 125 KBaud CAN network
250 KB
= 250 KBaud CAN network
500 KB
= 500 KBaud CAN network
1 MB
= 1 MBaud CAN network