Series

Application

Gemco Transducer

Comments

1746L

PLC direct input for the Allen

Bradley SLC 500 Chassis

951CP, VP, RS versions

952CP, VP2, RS versions

All 955D digital versions

High speed, high accuracy card that delivers

position data directly to the I/O image table

every 300 microseconds.

2120

LDT input module that

displays position and acts as

PLC interface

951VP-2110 version when a V1

board is specified. 951, 952 or 953 CP,

RS versions when an L1 board

is specified

Display reads in inches or millimeters.

Selectable BCD, Gray code, or Binary output.

Optional analog output to indicate position

and/or velocity. Optional output board

provides two relay outputs.

2110

Press shut height monitor

951VP-2110 version when a V1

board is specified. 951, 952 or 953 CP,

RS versions when an L1 board

is specified

Designed for press shut height. Offers

programmable bolster offset, zero offset,

movement direction, count direction, scale

offset, and negative overshoot. Decreases hit

to hit setup time and offers over-travel limits.

1996C

Press shut height controller

951CP versions,

952CP versions,

953CP versions

Automatically adjusts the ram up or down to

a pre-programmed shut height value for up to

500 jobs. Optional binary output.

1995L

(Consult Factory

for 4-20 Input )

Programmable Limit Switch

955 (0-10 VDC or 4-20mA),

951A voltage versions,

952A voltage versions,

953A voltage versions

Allows the transducer to have programmable

setpoints throughout the range of the sensor.

This unit has multiple program capability and

can expand up to 30 outputs.

Hand-Held Programmer

& PC Interface

951-1405

Allows 951

to be programmed in the

field

All 951

The field programmer allows for changes in

output, polarity, span, and calibration in the

transducer.

In Line Hand-Held Cable

SD0457900

Allows 951

to be programmed in the

field

All 951

Allows the user to plug in the hand-held

programmer. In Line Hand-Held Programmer

Patch Cable, use with Part Number 951-1405

In Line Active Zone

Programming Unit

955-1409

Allows 955S & 955A to be

programmed in the field

952 with Connector Option S,

953A, 955A, 955e, 955S, 956A, 956S

The field programmer allows for changes in

output, polarity, span, and calibration in the

transducer.

Battery Operated

Test/Programming Unit

SD0528810

Allows Voltage 955S & 955A

to be

programmed in

the field

952A, 953A

955A, 955e, 955S,

956A, 956S

The field programmer allows for changes in

output, polarity, span, and calibration in the

transducer.

Battery Operated

Test/Programming Unit

SD0528811

Allows Current 955S & 955A

to be

programmed in

the field

952A, 953A

955A, 955e, 955S,

956A, 956S

The field programmer allows for changes in

output, polarity, span, and calibration in the

transducer.