Series
Application
Gemco Transducer
Comments
1746L
PLC direct input for the Allen
Bradley SLC 500 Chassis
951CP, VP, RS versions
952CP, VP2, RS versions
All 955D digital versions
High speed, high accuracy card that delivers
position data directly to the I/O image table
every 300 microseconds.
2120
LDT input module that
displays position and acts as
PLC interface
951VP-2110 version when a V1
board is specified. 951, 952 or 953 CP,
RS versions when an L1 board
is specified
Display reads in inches or millimeters.
Selectable BCD, Gray code, or Binary output.
Optional analog output to indicate position
and/or velocity. Optional output board
provides two relay outputs.
2110
Press shut height monitor
951VP-2110 version when a V1
board is specified. 951, 952 or 953 CP,
RS versions when an L1 board
is specified
Designed for press shut height. Offers
programmable bolster offset, zero offset,
movement direction, count direction, scale
offset, and negative overshoot. Decreases hit
to hit setup time and offers over-travel limits.
1996C
Press shut height controller
951CP versions,
952CP versions,
953CP versions
Automatically adjusts the ram up or down to
a pre-programmed shut height value for up to
500 jobs. Optional binary output.
1995L
(Consult Factory
for 4-20 Input )
Programmable Limit Switch
955 (0-10 VDC or 4-20mA),
951A voltage versions,
952A voltage versions,
953A voltage versions
Allows the transducer to have programmable
setpoints throughout the range of the sensor.
This unit has multiple program capability and
can expand up to 30 outputs.
Hand-Held Programmer
& PC Interface
951-1405
Allows 951
to be programmed in the
field
All 951
The field programmer allows for changes in
output, polarity, span, and calibration in the
transducer.
In Line Hand-Held Cable
SD0457900
Allows 951
to be programmed in the
field
All 951
Allows the user to plug in the hand-held
programmer. In Line Hand-Held Programmer
Patch Cable, use with Part Number 951-1405
In Line Active Zone
Programming Unit
955-1409
Allows 955S & 955A to be
programmed in the field
952 with Connector Option S,
953A, 955A, 955e, 955S, 956A, 956S
The field programmer allows for changes in
output, polarity, span, and calibration in the
transducer.
Battery Operated
Test/Programming Unit
SD0528810
Allows Voltage 955S & 955A
to be
programmed in
the field
952A, 953A
955A, 955e, 955S,
956A, 956S
The field programmer allows for changes in
output, polarity, span, and calibration in the
transducer.
Battery Operated
Test/Programming Unit
SD0528811
Allows Current 955S & 955A
to be
programmed in
the field
952A, 953A
955A, 955e, 955S,
956A, 956S
The field programmer allows for changes in
output, polarity, span, and calibration in the
transducer.
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
AUTOMATION & PROCESS
TECHNOLOGIES
Misc.
Direct Connectivity
- 1986 MD Mill Duty Housing 1986H Servo Mount Resolver 1986GG Multi Turn Dual Resolver 1986G 3 1986F Standard Block Style Resolver 1986E 100mm Face Mount Resolver 1986D 3 1986C 2.06 1986B 2.25 1986A Standard Foot Mount Resolver 956 Blok Housing Option 955S Smart Brik LDT 955LC Brik LDT 955DQ Brik LDT 955D LDT 955C Brik 955A Brik LDT 955 eBrik 953 VMAX LDT 952 BlueOx LDT 950 MD Mill Duty Housing LDT 950IS Intrinsically Safe LDT