beautypg.com

953a/d/ssi vmax, 953 analog part numbering ssi part numbering – AMETEK 1986XPJ Explosion Proof Resolver User Manual

Page 29

background image

29

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com

AUTOMATION & PROCESS

TECHNOLOGIES

953

Analog Part Numbering

SSI Part Numbering

953A

0120

V0

X

Stroke Length

Insert stroke length to 0.1 inch. Enter as a four-place

number. Example: A 12.0” stroke enters as 0120.

OR

Insert stroke in millimeters to 1mm. Enter as a

four-place number. Example: 305mm stroke entered

as 0305M. Metric length includes metric mounting,

M18x1.5. Unless Specified Otherwise.

S

X

X

Null Zone

X

Standard 2 inches.

N

Insert non-standard Null Zone

(1.5” Minimum).
This value is called out in inches

regardless of units of measure

(i.e. 1.5” Null Zone = N1.5)

Units of Measure

Blank

Inches.

M

Metric

Options

X

None

S

Stainless Steel cover and

connector. Only available

with connector options S,

C, and H.

Dead Band

X

Standard 2.5 inches.

D

Insert non-standard Dead

Band (2.25” Minimum)
This value is called out in

inches regardless of units

of measure (i.e. 2.25”

Dead Band = D2.25)

Output

V0

0 to 10 VDC

V1

10 to 0 VDC

V2

-10 to 10 VDC

V3

10 to -10 VDC

V4

0 to 5 VDC

V5

5 to 0 VDC

V6

-5 to 5 VDC

V7

5 to -5 VDC

C4

4 to 20mA

C2

20 to 4mA

Connector Option

S

Standard 5 Pin, 12mm Euro

C_

Integral Cable Assembly. Insert length in

feet. Example: C6 = 6 foot cable.

M

6 Pin DIN, MTS Style D60

B

8 Pin DIN, Balluff S32

E

Environmental 10 Pin MS Connector

compatible w/951 & 952 LDTs w/

connector option “E”.

H_

High Temp., Integral cable assembly

200º C Teflon Cable. Insert length in feet.

Example: H6= 6 foot High Temp Teflon

Cable.

Optional Housing Style

- Mounting Threads

Blank

Raised face hex

base (standard) -

Threads will be the

same as “Units of

Measure” unless

specified otherwise.

R

US Threads with

raised face hex

base

F

US Threads with

flat face hex base

M

Metric Threads with

raised face hex

base

N

Metric Threads with

flat face hex base

C

Sensor cartridge

only - No hex base

VP

953S

0120

1

Stroke Length

1" to 300". Insert stroke length to 0.1 inch. Enter

as a four-place number. Example: A 12.0” stroke

enters as 0120.

OR

Insert stroke in millimeters to 1mm. Enter as

a four-place number. Example: 305mm stroke

entered as 0305. Metric length includes metric

mounting, M18x1.5. Unless Specified Otherwise

S

X

X

Null Zone

X

Standard 2 inches.

N

Insert non-standard Null Zone

(1.5” Minimum).
This value is called out in

inches regardless of units of

measure (i.e. 1.5” Null Zone

= N1.5)

Data Length

1

24 Bits

2

25 Bits

3

26 Bits

B

Data Format

B

Binary

G

Gray

X

Options

X

None

A

Alarm Bit 25, Parity 26

S

Stainless Steel cover and

connector. Only available with

connector options S, C and H.

Units of Measure

Blank

Inches

M

Metric

S

Position Update

S

Synchronous

A

Asynchronous

F

Direction

F

Measures Direction Forward

R

Measures Direction Reverse

V

Velocity

1

Resolution

1

.005mm

2

.01mm

3

.05mm

4

.1mm

5

.02mm

6

.002mm

7

.001mm

8

.00005"

9

.0001"

A

.0005"

B

.001"

Optional Housing Style

- Mounting Threads

Blank

Raised face hex

base (standard) -

Threads will be the

same as “Units of

Measure” unless

specified otherwise.

R

US Threads with

raised face hex

base

F

US Threads with

flat face hex base

M

Metric Threads with

raised face hex

base

N

Metric Threads with

flat face hex base

C

Sensor cartridge

only - No hex base

Connector Option

S

Standard 6 Pin, 12mm Euro

C_

Integral Cable Assembly. Insert length in feet. Example: C6 =

6 foot cable.

M

7 Pin DIN, MTS Style D70

B

8 Pin DIN, Balluff S32

E

Environmental 10 pin MS connector compatible with

SDO439700 LXX cable assembly

H_

High Temp., Integral cable assembly 200º C Teflon Cable.

Insert length in feet. Example: H6= 6 foot High Temp Teflon

Cable.

Dead Band

X

Standard 2.5 inches.

D

Insert non-standard Dead Band

(2.25” Minimum)
This value is called out in inches

regardless of units of measure (i.e.

2.25” Dead Band = D2.25)

953A/D/SSI VMAX

LDT