beautypg.com

7330 pro-stik ii – AMETEK 1986XPJ Explosion Proof Resolver User Manual

Page 56

background image

56

1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com

AUTOMATION & PROCESS

TECHNOLOGIES

7330

Intrinsically Safe

Programmable Linear Position Sensor

The 7330 Pro-Stik II sensor combines the reliability

and resolution of magnetostrictive continuous

absolute positioning sensing with the Stik sensor

package to create a unique level measuring

instrument.

The magnetostrictive technology is the same

as used in Gemco LDT sensors. Ametek liquid

level sensors have been proven in demanding

applications such as underground leak detection

and inventory management. The 7330 is available

with a rigid 316 stainless steel or flexible PVDF

materials.

All of the electronics are SMT components

integrated into the 5/8” diameter sensing tube. This

breakthrough in package design eliminates the

electronics enclosure at the top of the sensor, which

reduces the cost and offers greater options for

insertion and mounting in tanks and vessels.

Continuous position data is provided with resolution

of .014”. The two wire loop powered 4 to 20mA

intrinsically safe output is field programmable for

zero and span via a separate programming pin. The

position data is absolute and can be referenced

from the top or bottom of the probe.

The rugged, all welded 316 stainless steel

construction is ideal for industrial, food processing,

pharmaceutical, sanitary environments and

even hazardous areas requiring intrinsically safe

protection.

The sanitary and food grade versions of the Stik

are totally welded, ground and polished, and can be

easily installed with the Tri-clamp fitting. The 7330S

probe design eliminates unacceptable cracks and

crevices and is available in a 3-A CIP version or

food grade finish with a removable float. A variety of

floats, magnets, and mounting options are available

to fit virtually any application.

Specifications

Operating Voltage

13.5 to 30 VDC

Loop Impedance (R)

0 to 1000 @ 24 volts

Output

4 to 20mA

Operating Temperature

-20° to 70° C

Pressure Rating

1000 psi Max.

Resolution

0.025% full scale or 0.02” (whichever is greater)

Repeatablity

0.025% full scale or +/-0.020” (whichever is greater)

Accuracy

0.1% or .050” (whichever is greater)

Enclosure:

Material

Rating

Probe: 316 SS or PVDF

IP68

Probe Length

Stainless Steel

20” to 288”

Null Zone

8”

Dead Band

2”

Intrisically Safe Barrier

Voc less than or equal to 31 VDC

Isc less than or equal to 165mA

Approvals

Hazardous Areas Approvals

FM, CSA

-20°

Tamb

70° C

Class I, II, III, Div. 1

Groups C, D, E, F, G, T4

Class I, Div. 2

Groups A, B, C, D, T4

Class I, Zone 0, AEx ia IIB T4

ATEX

Ex ia IIB T4

NEMKO 04 ATEX 1357X

0344 EX II 1G

Specifications may change without notice. Patented.

7330F

Shown with

optional float kit.

7330X

Shown with

optional tube

coupling, bushing

and float kit.

7330X

Shown with

optional tube

coupling and large

split magnet.

7330 Pro-Stik II

APPROVED

C

US

FM