955

Input Voltage

13.5 to 30 VDC

Current Draw

2.5 Watts Maximum,

120 mA@15 VDC Typical

Output

Analog: 0 to 10VDC, 10 to 0 VDC,

4 to 20 mA, 20 to 4mA.

Digital: Control Pulse, Variable

Pulse, Start/Stop

Quadrature: A+, A-, B+, B-, Z+ ,Z-

Line Drivers: 5V or Input Power

Resolution

Internal:

Analog Output:

Digital Output:

Quadrature:

Non-Linearity

+/- 0.05% of Stroke

Repeatability

+/- 0.006% of Full Stroke

Hysteresis

+/- 0.02% of Full Scale

Update

Analog

50” or less:

51” to 100”:

101” to 150”:

151” to 180”:

Digital

Operating Temperature

-20

to 70

C

Span Length

5” to 180”

Null Zone

3.00”

Dead Zone

2.00”

LED

Tricolor diagnostic LED for communication of

LDT status.

Connector

955CA:

955CD:

955C DQ:

Approvals

CE

Enclosure

IP 67

IP 68 Optional

0.001”

16 Bit (1 part in 65,535)

Controller Dependent

0.001”

1ms

2ms

3ms

4ms
Controller Dependent

Specifications are subject to change without notice.

Specifications are based on a typical 36” LDT.

SPECIFICATIONS

o

o

Standard 5 Pin Micro 12mm Euro Connector
Standard 6 Pin Micro 12mm Euro Connector
Standard 12 Pin Micro (option E)
12mm Euro Connector or 10 Pin HRS (option H)

LDT Specifications

It is recommended to use one mounting

bracket on each end and every 3 feet between.

It is recommended to use one pair of mounting

brackets on each end and every 3 feet between.

Side Mounting Foot

Part No. SD0559200

End Mounting Foot

Part No. SD0530600

Top Mounting Foot

Part No. SD0522000

Mounting Options for the 955C