955lc brik, Part numbering, Wiring diagram – AMETEK 1986XPJ Explosion Proof Resolver User Manual
Page 34: Sensing surface
34
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
AUTOMATION & PROCESS
TECHNOLOGIES
955
Part Numbering
Accessories
Item
Part Number
Slide Magnet
SD0521800
Floating Magnet
SD0522100
Wide Floating Magnet
SD0551500
Mounting Foot
SD0522000
6 Ft., 4 Pin Cable
949001L6
12 Ft., 4 Pin Cable
949001L12
6 Ft. Cable; Right Angle Connector
949002L6
12 Ft. Cable; Right Angle Connector
949002L12
Program Module
955-1412
Use Euro Connector (micro 12 mm single
keyway) cordsets, available from most connector
manufacturers or purchased from Ametek. Install
according to the following diagrams:
Connector View
Wiring Diagram
3
2
4
1
Power 24VDC
(brown wire)
Output
(black wire)
Ground
(blue wire)
No Connection
955LC
0120
V0
Stroke Length
Insert stroke to 0.1” as a four-place number, enter
12.0” stroke as 0120; to convert metric strokes,
multiply millimeter value by 0.03937 for inch value.
Output
V0
0 to 10 VDC
V1
10 to 0 VDC
C4
4 to 20mA
C2
20 to 4mA
Sensing Surface
N
S
Note: The North side of a floating
magnet will face the LDT’s sensing
surface.
955LC BRIK
- 1986 MD Mill Duty Housing 1986H Servo Mount Resolver 1986GG Multi Turn Dual Resolver 1986G 3 1986F Standard Block Style Resolver 1986E 100mm Face Mount Resolver 1986D 3 1986C 2.06 1986B 2.25 1986A Standard Foot Mount Resolver 956 Blok Housing Option 955S Smart Brik LDT 955LC Brik LDT 955DQ Brik LDT 955D LDT 955C Brik 955A Brik LDT 955 eBrik 953 VMAX LDT 952 BlueOx LDT 950 MD Mill Duty Housing LDT 950IS Intrinsically Safe LDT