953a/d/ssi vmax – AMETEK 1986XPJ Explosion Proof Resolver User Manual
Page 31
![background image](/manuals/409725/31/background.png)
31
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
AUTOMATION & PROCESS
TECHNOLOGIES
953
Optional Housing Style
- Mounting Threads
Blank
Raised face hex
base (standard) -
Threads will be the
same as “Units of
Measure” unless
specified otherwise.
R
US Threads with
raised face hex
base
F
US Threads with
flat face hex base
M
Metric Threads with
raised face hex
base
N
Metric Threads with
flat face hex base
C
Sensor cartridge
only - No hex base
Optional Housing Style
- Mounting Threads
Blank
Raised face hex
base (standard) -
Threads will be the
same as “Units of
Measure” unless
specified otherwise.
R
US Threads with
raised face hex
base
F
US Threads with
flat face hex base
M
Metric Threads with
raised face hex
base
N
Metric Threads with
flat face hex base
C
Sensor cartridge
only - No hex base
953 LED Output Summary
Output
953A
953D
953SSI
Flashing Red
Flash memory corrupt
Flash memory corrupt
Flash memory corrupt
Flashing Red/Green
EE memory corrupt
EE memory corrupt
EE memory corrupt
Flashing Green
N/A
N/A
N/A
Flashing Yellow
Communication/programming mode
Communication/programming mode
Communication/programming mode
Fast Flashing Yellow
Programming input held asserted
Interrogation input held asserted
Clock input held asserted
Solid Red
No magnet signal detected
No magnet signal detected
No magnet signal detected
Green/Red Blip (1s to 0.12s)
N/A
Max Gain but signal detected and within range
Max Gain but signal detected and within range
Solid Green
Magnet signal detected and within the
programmed range
Normal probe operation; magnet signal and
interrogation pulse detected
Normal probe operation; magnet signal
and SSI clock operational
Solid Yellow
Magnet signal detected outside of the
programmed range
No external interrogation pulse detected
No SSI clock pulses detected
Yellow/Red Blip (1s to 0.12s)
N/A
N/A
SSI clock pulses do not match
LDT SSI data length
Green/Yellow Blip (1s to 0.12s)
N/A
N/A
LDT data not synchronous with controller
(if LDT is programmed for synchronous mode)
953A/D/SSI VMAX
™
LDT
- 1986 MD Mill Duty Housing 1986H Servo Mount Resolver 1986GG Multi Turn Dual Resolver 1986G 3 1986F Standard Block Style Resolver 1986E 100mm Face Mount Resolver 1986D 3 1986C 2.06 1986B 2.25 1986A Standard Foot Mount Resolver 956 Blok Housing Option 955S Smart Brik LDT 955LC Brik LDT 955DQ Brik LDT 955D LDT 955C Brik 955A Brik LDT 955 eBrik 953 VMAX LDT 952 BlueOx LDT 950 MD Mill Duty Housing LDT 950IS Intrinsically Safe LDT