950is intrinsically safe, The gemco 950is intrinsically safe ldt, 950is – AMETEK 1986XPJ Explosion Proof Resolver User Manual
Page 12: Dimensions & wiring diagram, Automation & process technologies, 24o volt 6o hz application (optional), 120 volt 6o hz application
12
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
AUTOMATION & PROCESS
TECHNOLOGIES
950IS
Dimensions & Wiring Diagram
13
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
950IS
Dimensions & Wiring Diagram
950IS Intrinsically Safe
4 FOOT CABLE WITH CORD GRIP
3/4-16 THREAD
TRANSDUCER, 950 1445, SHOWN
FOR REFERENCE ONLY
2.00" NULL BAND
GUIDE TUBE
316 S.S.
TUBE LENGTH
CONNECT BLACK WIRE (-) TO BLACK WIRE
AND YELLOW WIRE (+) TO WHITE WIRE.
5.00" DEAD BAND
7.81"
O%
1OO%
SPAN
1.13"
Y
W
B
B
V1
V2
INCREASING
MODE
2O
MA.
POSITION "A"
POSITION "B"
1OO%
UPPER ANALOG RANGE
O%
LOWER ANALOG RANGE
MAXIMUM ACTIVE
LENGTH OF
MAGNET MOVEMENT
(STROKE LENGTH
MINIMUM
RANGE
(ABOVE CONNECTIONS FOR BELDEN 9182
CABLE TO TRANSDUCER UNIT)
SEALED JUNCTION BOX, BY OTHERS.
NON-HAZARDOUS LOCATION
HAZARDOUS LOCATION
CLASS II, DIV. 1, GROUP E, F & G
CLASS III, DIV. 1
CLASS I, DIV. 1, GROUP C & D
APPROVED SEAL
10
VOLTS
0
VOLTS
4
MA.
VOLTS
MA.
VOLTS
4
0
MA.
10
20
DECREASING
MODE
GUIDE TUBE CLOSURE
JAM NUT
IN INCHES)
.31"
MAGNET ASSEMBLY
1.28" DIAMETER
.40 DIA.
24O V 6O HZ
L1 L2 G
3
1
4
2
L1
L2
G
950 1446
TRANSMITTER
24O VOLT 6O HZ APPLICATION (Optional)
SPAN ADJUSTMENT (CLOCKWISE TO INCREASE)
MINIMUM RANGE ADJUSTMENT (CLOCKWISE TO DECREASE)
120 VOLT 6O HZ APPLICATION
POSITIVE POTENTIAL, RESPECT TO GROUND,
STAHL MODEL No. 9001/01-280/165/00.
DC-RESISTIVE, FUSED SAFETY BARRIER,
END ONLY.
CONTROLLER
GROUND SHIELD AT
(1O MA. MAXIMUM)
TO ASSOCIATED EQUIPMENT
(1,OOO OHM LOOP CIRCUIT MAXIMUM)
4-2O MA. ISOLATED OUTPUT
TO ASSOCIATED EQUIPMENT
ISOLATED OUTPUT
PANEL
GROUND TO
CONDUIT WITH CABLE. SEE NOTES FOR
120 V 6O HZ
L N G
1O-O
O-1O
Y
B
3 4
1
B
Y
SLAVE INPUT
O-1O (V1)
1O-O (V2)
+ 4-20 MA
XDUCER -
XDUCER +
NOT USED
GND
RANGE
(INSTALLED) *
950 1446
TRANSMITTER
(6 VA. MAXIMUM)
6OHZ A. C. LINE
TO 120 VOLT
L
N
G
1
MODE
2
(SEE INSTRUCTIONS BELOW FOR DETAILS)
IF RANGE MODE IS REQUIRED.
REMOVE COVER AND MOVE JUMPER
JUMPER FOR LEVEL/RANGE MODE.
(OPEN CHASSIS AVAILABLE)
NEMA ENCLOSURE AS SPECIFIED
1
MODE
LEVEL
MIN.R.
SPAN
1
CABLE PARAMETER DETAILS.)
IS FOR BELDEN 9182 CABLE. SEE
IN THIS CONDUIT.) (COLOR CODE SHOWN
DETAILS. (NO OTHER WIRES PERMITTED
WHEN USED WITH APPROPRIATE SAFETY BARRIER
UL LISTED INTRINSICALLY SAFE
CLASS III, DIV. 1
CLASS II, DIV. 1, GROUP E, F & G
CLASS I, DIV. 1, GROUP C & D
FOR USE IN HAZARDOUS LOCATIONS:
** INSERT STROKE LENGTH IN INCHES.
TRANSDUCER 950 1445-**
A
B
6
2
NOTES
CABLE PARAMETERS
A. USE CONDUIT WITH CABLE INSIDE.
B. NO OTHER WIRES TO BE IN CONDUIT.
C. UP TO 1OOO FEET- #22 AWG OR GREATER, TWISTED SHIELDED
CABLE, CAPACITY LESS THAN 6O PICOFARAD PER FOOT,
INDUCTANCE LESS THAN .2 MICROHENRIES PER FOOT.
D. UP TO 25OO FEET- TWIN AXIAL BELDEN 9182 OR EQUAL. (8.8 PICO
FARADS PER FOOT).
CALIBRATION INSTRUCTIONS
1. POSITION THE MAGNET AT THE UPPER LIMIT OF THE ANALOG SPAN
REQUIRED (POSITION A). WHILE READING OUTPUT V1 (i.e. O-1O TO
GROUND), ADJUST THE "MIN.R." ADJUSTMENT SCREW TO READ
1O.OO VOLTS.
2. CHANGE POSITION OF THE MAGNET TO THE LOWER LIMIT OF THE
ANALOG SPAN (POSITION B). WHILE STILL READING V1, TURN THE
"SPAN" ADJUSTMENT SCREW TO READ O.OO VOLTS.
3. IF THE 4 TO 20mA OUTPUT IS REQUIRED, DETERMINE WHICH MODE
OF OPERATION IS REQUIRED AND SELECT THE REQUIRED POSITION
OF THE MODE JUMPER. LEVEL MODE - CURRENT INCREASES ON
RISING LEVEL. RANGE MODE - CURRENT INCREASES ON FALLING
LEVEL. THE 0 TO 10 OR 10 TO 0 VOLT OUTPUTS ARE ALWAYS
PRESENT.
4. THE 950 TRANSMITTER IS NORMALLY SHIPPED WITH THE JUMPER IN
LEVEL MODE. THE COVER MUST BE REMOVED BY FIRST REMOVING 4
STAND-OFF SCREWS AND COVER BEFORE CHANGING THE MODE
JUMPER.*
*LEVEL MODE - JUMPER ACROSS THE UPPER TWO PINS - POSITION 1.
RANGE MODE - JUMPER ACROSS THE LOWER TWO PINS - POSITION 2.
24 VDC (AT TERMINAL “NOT USED”) WILL NOT SUPPORT ANY
ADDITIONAL LOADS.
GENERAL INFORMATION
PRIOR TO INSTALLATION, POWER UP THE SYSTEM TO VERIFY
OPERATION AND TO FAMILIARIZE YOURSELF WITH THE UNIT.
SEE DRAWING E0198300-B WHEN UL APPROVAL IS REQUIRED ON
TRANSDUCER UNIT.
THE TRANSDUCER SHOULD BE HANDLED WITH CARE DURING STORAGE
AND INSTALLATION.
TO 240 VOLT
60HZ AC LINE
(6 VA MAX)
(OPTIONAL,
ONLY WHEN
ORDERED)
NEMA ENCLOSURE
AS SPECIFIED
(OPEN CHASSIS
AVAILABLE)
The Gemco 950IS Intrinsically Safe LDT
- 1986 MD Mill Duty Housing 1986H Servo Mount Resolver 1986GG Multi Turn Dual Resolver 1986G 3 1986F Standard Block Style Resolver 1986E 100mm Face Mount Resolver 1986D 3 1986C 2.06 1986B 2.25 1986A Standard Foot Mount Resolver 956 Blok Housing Option 955S Smart Brik LDT 955LC Brik LDT 955DQ Brik LDT 955D LDT 955C Brik 955A Brik LDT 955 eBrik 953 VMAX LDT 952 BlueOx LDT 950 MD Mill Duty Housing LDT 950IS Intrinsically Safe LDT