Red Lion GEMINI 33 User Manual
Page 8
FACTORY SETTINGS
INITIAL FACTORY CONFIGURATION
Keys Struck
Display
Description
4,3
43
1
Count with Inhibit
4,4
44
1
Count on falling edge of Input A
4,5
45
1
Scale Multiplier of 1.0
4,6
46
1
Leading zero blanking and no decimal point
5,2
52
5
Output 1 terminates after Timed Output, Normal Phase
5,3
0000.10
Timed Output 1 Value of 0.1 sec
5,4
54
5
Output 2 terminates after Timed Output, Normal Phase
5,5
0000.10
Timed Output 2 Value of 0.1 sec
6,1
61
4
Reset Process, Batch, and Total Counter
6,2
62
1
Process Counter, Manual Reset to Zero
6,3
63
1
Batch Counter, Manual Reset to Zero
6,4
64
3
Output B terminates at reset. Normal output phase
6,5
0000.10
Timed Output B Value of 0.1 sec
6,6
66
6
Presets, Scale Factor 2-Button Reset, & Counter
Load Programming Enabled
3
01.0000
Scale Factor set to 1.0000
1
000100
Preset 1 set to 100 (when Process Count displayed)
2
000200
Preset 2 set to 200 (when Process Count displayed)
1
000010
Preset B set to 10 (when Batch Count is displayed)
E & +/-
000000
Counter Load Values set to 0 (displays value for
displayed counter)
Note: Entering a -1 in function code 41 will restore the unit to the factory configuration
shown above.
-6-