APPENDIX “A” - INSTALLATION & INPUT CONFIGURATION SWITCH SET-UP

Before installing the Gemini 3300 into the panel, the user should first

become familiar with the unit. It may also be desirable to program the unit and

appropriate DIP switches for the application at hand (Refer to the

“Programming and Applications” sections). Once the unit is programmed,

the settings will be saved in memory. The Program Disable “PGM. DIS.”

terminal should be connected to “COMM.” to prevent accidental or

unauthorized programming changes.

INSTALLATION ENVIRONMENT

The unit should be installed in a location that does not exceed the maximum

operating temperature and provides good air circulation. Placing the unit near

devices that generate excessive heat should be avoided.

The bezel should be cleaned only with a soft cloth and neutral soap

product. Do NOT use solvents.

Continuous exposure to direct sunlight may accelerate the aging process of

the bezel.

Do not use tools of any kind (screwdrivers, pens, pencils, etc.) to operate

the keypad of the unit.

The Gemini 3300 meets NEMA 4/IP65 requirements for indoor use,

when properly installed. The units are intended to be mounted into an

enclosed panel. Two mounting clips and screws are provided for easy

installation. Consideration should be given to the thickness of the panel. A

panel which is too thin may distort and not provide a water-tight seal.

(Recommended minimum panel thickness is 1/8".)

After the panel cut-out has been completed and deburred, remove the

backing from the adhesive side of the gasket, and carefully apply the

gasket to the panel. DO NOT APPLY THE ADHESIVE SIDE OF THE

GASKET TO THE COUNTER BEZEL. Insert the unit into the panel.

Install the screws into the narrow ends of the mounting clips as shown in

the drawing to the left. Thread the

screws into the clips until the pointed

end just protrudes through the other

side.

Install each of the two mounting

clips by inserting the wide lip of the

clips into the wide end of the holes

located on either side of the case.

Tighten the screws evenly, applying

uniform compression, thus providing a

water-tight seal.

Caution: Only minimum pressure is

required to seal panel. Do NOT over tighten mounting screws.

-26-

PANEL MOUNTING (Note, See Appendix “B” for Dimensions)