STEP BY STEP PROGRAMMING OF THE GEMINI 3300 (Cont’d)
STEP 8 - Enter Code 62 (Process Counter Reset Action Modes), and enter a 1
(Manual Reset to Zero with Preset Tracking enabled).
STEP 9 - Enter Code 63 (Batch Counter Reset Action Modes), and enter a 2
(Manual Reset to Batch Preset).
STEP 10 - Enter Code 64 (Batch Output Termination Modes), and enter a
mode identifier of 3 (Terminate at Manual Reset).
STEP 11 - Enter Code 66 (“Operator Accessible Functions” Mode), and
enter a mode identifier of 5, (Preset, Counter Load programming,
2-Button Reset and Reset enabled). When the “PGM. DIS.” (program
disable) terminal is connected to COMMON, the only changes that will be
possible is resetting the unit and changing Preset 2 and Preset B. Preset 1 is
locked out when Preset tracking is enabled. The Preset 1 value should be
entered before “PGM. DIS.” terminal is connected to COMMON.
STEP 12 - Press the “+/-” key until the Process Count is displayed (P
annunciator is displayed). Press “1” and enter the value at which the
machine is to start slowing down (900 is used in this application).
STEP 13 - Press “2” and enter the total length of material to be processed
(1000 feet).
STEP 14 - Press the “+/-” key until the Batch Count Value is displayed (B
annunciator is displayed). Press “1” and enter the amount of spools to be
wound.
STEP 15 - Press “3” and enter a Scale Factor Value of 4.1667
STEP 16 - Connect the “PGM. DIS.” terminal to “COMM.” to prevent
accidental changes to the program modes.