Red Lion GEMINI 33 User Manual
Page 7

The Timed Output Values are changed by entering two-digit function
codes. After the code is entered, the display will show the present Timed
Output 1, 2 or B Value in seconds with two decimal place resolution. The
Timed Output Values can be set from .01 to 599.99 seconds.
To change the Timed Output 1 Value, enter function
code 53 and enter the new value by holding down or
repeatedly pressing the key below the digit position you
wish to change.
The new value will be entered when the “E” key is
pressed. The display will immediately return to the
count value.
Note: A Timed Output Value of zero cannot be programmed into the Gemini
3300. If a value of 0 is entered into the display, and the “E” key is pressed,
the unit will remain in data entry mode. If a new value is not entered, it will
time out and the unit will continue to use its previous setting.
As with the other functions, you must press “E” to record the changes. For
the data entry modes, if you do not press the “E” key, a time out of 5 seconds
occurs, and the display returns to operating mode without any changes to the
value. The only time any change will occur is when the “E” key is pressed.
It is possible to change the counter values of the Gemini 3300 by entering a
“Counter Load Value”. This feature can be enabled or disabled by the
programming of the “Operator Accessible Functions Modes”, function code
66. The “Counter Load Value” is stored when the unit is powered down. To
access the Counter Load Value for the desired counter;
first, press the “+/-” key, if necessary, so that the display is
indicating the counter that is to be changed.
Secondly, press the “E” key and while holding it down,
press the “+/-” key.
The Gemini will now display the Counter Load Value
for the Counter that is displayed.
To change the value, press the key under the digit to be
changed as explained previously for the Preset.
To load the value into the counter, press the “E” key.
The display will flash momentarily and will display the
counter with the new value.
-5-