beautypg.com

Red Lion GEMINI 33 User Manual

Page 7

background image

The Timed Output Values are changed by entering two-digit function

codes. After the code is entered, the display will show the present Timed

Output 1, 2 or B Value in seconds with two decimal place resolution. The

Timed Output Values can be set from .01 to 599.99 seconds.

To change the Timed Output 1 Value, enter function

code 53 and enter the new value by holding down or

repeatedly pressing the key below the digit position you

wish to change.

The new value will be entered when the “E” key is

pressed. The display will immediately return to the

count value.

Note: A Timed Output Value of zero cannot be programmed into the Gemini

3300. If a value of 0 is entered into the display, and the “E” key is pressed,

the unit will remain in data entry mode. If a new value is not entered, it will

time out and the unit will continue to use its previous setting.

As with the other functions, you must press “E” to record the changes. For

the data entry modes, if you do not press the “E” key, a time out of 5 seconds

occurs, and the display returns to operating mode without any changes to the

value. The only time any change will occur is when the “E” key is pressed.

It is possible to change the counter values of the Gemini 3300 by entering a

“Counter Load Value”. This feature can be enabled or disabled by the

programming of the “Operator Accessible Functions Modes”, function code

66. The “Counter Load Value” is stored when the unit is powered down. To

access the Counter Load Value for the desired counter;

first, press the “+/-” key, if necessary, so that the display is

indicating the counter that is to be changed.

Secondly, press the “E” key and while holding it down,

press the “+/-” key.

The Gemini will now display the Counter Load Value

for the Counter that is displayed.

To change the value, press the key under the digit to be

changed as explained previously for the Preset.

To load the value into the counter, press the “E” key.

The display will flash momentarily and will display the

counter with the new value.

-5-