APPENDIX “D” - GEMINI 3300 BATCH COUNTER MODE FUNCTION COMMAND CODE SUMMARY
-38-
CODE
MODE
DESCRIPTION
COMMENTS
41
LOAD FACTORY SETTINGS
+/-
Batch Counter
(-) Loads factory set code values*
43
INPUTS A & B RESPONSE MODES (counter only)
1
Count with Inhibit
Input A = Count, Input B = Inhibit
2
Count with Up/Down Control
Input A = Count, Input B = Up/Down
3
Add/Subtract
Input A = Add, Input B = Subtract
4
Anti-Coincidence Add/Add
Input A = Add, Input B = Add
5
Quadrature
Input A = Count, Input B = Quadrature
6
Quadrature x4
Input A = Count & Quad, Input B = Count & Quad
44
NUMBER OF COUNT EDGES
Cannot be programmed in Quad x4.
1
Single Edge Counting (x) 1
Count on falling edge of count input.
2
Double Edge Counting (x2)
Count on both edges of count input.
45
SCALE MULTIPLIER
1
1
2
0.1
3
0.01
4
0.001
46
DECIMAL POINT & LEADING ZERO BLANKING
-
(+) Leading Zero Blank Enabled
-
(-) Leading Zero Blanking Disabled
*
+/-1
No Decimal Point
+/-2
Decimal Point Right of Digit 2
+/-3
Decimal Point Right of Digit 3
+/-4
Decimal Point Right of Digit 4
+/-5
Decimal Point Right of Digit 5
+/-6
Decimal Point Right of Digit 6
*Polarity sign is displayed in front of the identifier, a (-) sign is displayed, a (+) sign is not.