PROGRAMMING FUNCTION CODES
Entering function and mode is easily accomplished by
pressing the appropriate digit key. To program the Scale
Multiplier, you would enter 45 by pressing the front panel
keys, 4 and 5.
The digits on the left side of the display show the
function code; the digits on the right side show the current
programmed mode.
A new mode selection is made by entering a new
number. On some of the entries, you have the option of a
plus “+” or minus “-” sign. In the cases where a “+” sign is
required, no sign will be displayed. If you do enter a “-”
sign (using the “+/-” key), a minus sign will be displayed
in front of the appropriate digit.
Pressing the “E” key finalizes the change. The display
will now show the count value immediately.
If you do not press the “E” key, the change will not be
recorded. The display will remain in the programming mode
for 15 seconds, and then return to normal operating mode
using the old function and mode settings.
The unit can be programmed with the factory settings by
calling up Function Code 41, putting a “-” in front of the
mode by pushing the “+/-” key, and entering it.
Refer to the “Factory Settings” section for more details.
PROGRAMMING THE PRESETS, SCALE FACTOR, TIMED
OUTPUTS & COUNTER LOAD VALUES
The Presets and Scale Factor Values are commonly reprogrammed on a daily
basis. As such, single keystroke access has been provided on the front panel.
Pressing the “3” key will call up the Scale Factor.
Once the Scale Factor is displayed, changing the digits
can be accomplished by repeatedly pressing the key beneath
the digit position you wish to change or by holding the key
down, allowing the digit to increment automatically.
The new value will be entered when the “E” key is pressed.
The internal unscaled Process and Total Count Values
are multiplied by the Scale Factor Value, which changes
the displayed values accordingly.
Presets 1 and 2 are assigned to the Process Counter and the Batch Preset is
assigned to the Batch Counter. To call up the Preset for the desired counter,
the Gemini 3300 must first be displaying that count value.
To display the Preset 1 Value (Process Counter), the
“+/-” key is first pushed (if necessary) until the “P”
(Process) annunciator is lit.
The “1” key is then pushed to call up the Preset 1 Value.
To change the value, the digits can be cycled through in
the same manner as discussed for the Scale Factors.
The new value will be entered when the “E” key is pressed.
The Preset 2 Value is changed in the same manner as
described above except that the “2” key is pushed instead
of “1”. To change the Batch Preset, the “1” key is pushed
while the Batch Counter is being displayed. The Preset
Values can range from 0 to +999999.