APPENDIX “D” - GEMINI 3300 BATCH COUNTER MODE FUNCTION COMMAND CODE SUMMARY
-39-
CODE
MODE
DESCRIPTION
COMMENTS
52
OUTPUT 1 TERMINATION
-
(+) Normal Phase
Output normally “OFF”, turns “ON” at preset.
-
(-) Reverse Phase*
Output normally “ON”, turns “OFF” at preset.*
+/-1
Terminate at Output 2 Start
+/-2
Terminate at Output 2 End
+/-3
Terminate at Manual Reset
+/-4
Terminate at Manual Reset End
+/-5
Terminate at Output 1 Time Delay
53
NA
TIMED OUTPUT 1 VALUE
Range 0.01 to 599.99 sec.
54
OUTPUT 2 TERMINATION MODES
-
(+) Normal Phase
Output normally “OFF”, turns “ON” at preset.
-
(-) Reverse Phase*
Output normally “ON”, turns “OFF” at preset.*
+/-1
Terminate at Output 1 Start
+/-2
Terminate at Output 1 End
+/-3
Terminate at Manual Reset
+/-4
Terminate at Manual Reset End
+/-5
Terminate at Timed Output 2
55
TIMED OUTPUT 2 VALUE
Range 0.01 to 599.99 sec.
61
RESET BUTTON & TERMINAL ACTUATION MODES
-
(+) Maintained
Unit remains reset at long as reset is activated
-
(-) Momentary*
Unit will reset instantly and will start counting again even if reset is
still activated
+/-1
Reset Process Counter
+/-2
Reset Batch Counter
+/-3
Reset Process and Batch Counter
+/-4
Reset Process, Batch and Total Counter
*Polarity sign is displayed in front of the identifier, a (-) sign is displayed, a (+) sign is not.