APPENDIX “D” - GEMINI 3300 BATCH COUNTER MODE FUNCTION COMMAND CODE SUMMARY

-39-

CODE

MODE

DESCRIPTION

COMMENTS

52

OUTPUT 1 TERMINATION

-

(+) Normal Phase

Output normally “OFF”, turns “ON” at preset.

-

(-) Reverse Phase*

Output normally “ON”, turns “OFF” at preset.*

+/-1

Terminate at Output 2 Start

+/-2

Terminate at Output 2 End

+/-3

Terminate at Manual Reset

+/-4

Terminate at Manual Reset End

+/-5

Terminate at Output 1 Time Delay

53

NA

TIMED OUTPUT 1 VALUE

Range 0.01 to 599.99 sec.

54

OUTPUT 2 TERMINATION MODES

-

(+) Normal Phase

Output normally “OFF”, turns “ON” at preset.

-

(-) Reverse Phase*

Output normally “ON”, turns “OFF” at preset.*

+/-1

Terminate at Output 1 Start

+/-2

Terminate at Output 1 End

+/-3

Terminate at Manual Reset

+/-4

Terminate at Manual Reset End

+/-5

Terminate at Timed Output 2

55

TIMED OUTPUT 2 VALUE

Range 0.01 to 599.99 sec.

61

RESET BUTTON & TERMINAL ACTUATION MODES

-

(+) Maintained

Unit remains reset at long as reset is activated

-

(-) Momentary*

Unit will reset instantly and will start counting again even if reset is

still activated

+/-1

Reset Process Counter

+/-2

Reset Batch Counter

+/-3

Reset Process and Batch Counter

+/-4

Reset Process, Batch and Total Counter

*Polarity sign is displayed in front of the identifier, a (-) sign is displayed, a (+) sign is not.