background image

APPENDIX “D” - GEMINI 3300 BATCH COUNTER MODE FUNCTION COMMAND CODE SUMMARY

-41-

CODE

MODE

DESCRIPTION

COMMENTS

66

“OPERATOR ACCESSIBLE FUNCTIONS” MODES

“PGM.DIS” Terminal connected to “Comm”

-

(+) Reset Button & “RST” Terminal Enabled

Front panel reset can be independently disabled by using DIP

switch.

-

(-) Reset Button & “RST” Terminal Disabled*

Both front panel and rear terminal are disabled.

+/-1

No Functions Enabled

+/-2

Preset Programming Enabled

+/-3

Scale Factor Programming Enabled

+/-4

Preset & Scale Factor Programming Enabled

+/-5

Preset, 2-Button Reset & Counter Load Programming Enabled

+/-6

Preset, Scale Factor, 2-Button Reset & Counter Load

Programming Enabled

1

Display P

PROCESS PRESET 1

Up to +999999

1

Display B

BATCH PRESET

Up to +999999

2

Display P

PROCESS PRESET 2

Up to +999999

3

SCALE FACTOR

Up to +5.9999

E & +/- Disp P, B, T COUNTER LOAD VALUE

Up to +999999. Counter load value is saved in memory when

power is removed.

E & 1

RESET PROCESS COUNTER

E & 2

RESET BATCH COUNTER