beautypg.com

Red Lion GEMINI 33 User Manual

Page 5

background image

Counter will display the number of batches that have been completed (up-count

modes) or the number of batches left to complete (down-count modes).

The Total Count is the total number of counts that have been received since

the Total was last reset. It can be used to keep a running total of process units

on a desired per shift, per day, per week, etc. basis. Like the Process and Batch

Counts, the Total can be reset independently of the other two.

The internal precision of the Process and Totalizing Counter is maintained

to 9 digits. The internal precision of the Batch Counter is 7 digits.

PROGRAMMING THE GEMINI 3300

When your Gemini 3300 arrives from the factory, it is necessary to

program the unit to suit the desired application. It is programmed with the

factory settings listed in the “Factory Settings” section. All programming is

accomplished by using the pushbuttons located on the front panel. The

personality, functions, and modes are accessed by pressing the appropriate

keys. A function is defined by a two-digit code which appears on the left side

of the display. The mode of that function is shown as a one-digit code on the

right side of the display. At times there will be a “-” sign modifier to the left of

the mode.

Data for the Presets, Scale Factors and Timed Output Values are entered

differently. Each digit key controls the digit on the display directly above it.

Changing the digits can be done by repeatedly pressing the key beneath the

digit position you wish to change or by holding the key down. As you hold it

down, or repetitively press it, the value of that digit will change cyclically,

counting up to 9, then to 0, and then up again. The 6 numbered keys

correspond to the six digits, and the “+/-” key corresponds to polarity.

DISPLAYING THE PROCESS, BATCH & TOTAL COUNT

VALUES

The Gemini 3300 can display any of the three count values. There are three

annunciators to the left of the display with the designations, P, B, and T. Only

one annunciator will be lit at one time. These annunciators correspond to the

Process, Batch and Total count values. To display a different value, the “+/-”

key is repeatedly pressed and released until the annunciator corresponding to

the desired count value is displayed. Each time the key is pressed, the display

will sequence to the next count value and the appropriate annunciator will

light. Once the display has been changed, the unit will display the count value

until it is changed again.

MANUAL RESET

There are two different methods by which the Gemini 3300’s count values

can be manually reset. These methods are as follows:

Reset by front panel Reset button, “R”

Rear Reset terminal

Reset utilizing 2-button reset

The reset operation is affected by three function code settings; The Reset

Button, and Reset Terminal Actuation modes (Function Code 61), the Reset

Action modes (Function Codes 62 and 63), and the “Operator Accessible

Functions” modes (Function Code 66). The “Reset Button and Terminal

Actuation Modes” will determine which counters will be reset when the Reset

button or terminal is activated. The Reset Action modes determine whether

the Process or Batch Counter will Reset to Zero or Reset to Preset. The

“Operator Accessible Functions” modes will determine which resetting

modes are enabled, when the “PGM. DIS.” (program disable) terminal is

connected to “COMMON”. The Reset button can be disabled independently

of the Reset terminal by setting the “DIS./EN.RST.” position of the Input

Configuration DIP switches to “DIS.”.

A 2-button reset method is provided to allow an independent reset for the

Process and Batch counters. To reset a counter using this method, the

following procedure must be used.

Press the “E” key,

While holding the “E” key also press the

“1” button to reset the Process Counter, or the

“2” button to reset the Batch Counter.

Note: There is no 2-button reset mode for the Total Counter. It can be

independently reset by loading a Counter Load Value of 0.

-3-