Hp snmp agent and hp cim provider events, Alarms – HP OneView for VMware vCenter User Manual
Page 118
Enclosure name: Power subsystem status changed to non-recoverable error.
Enclosure name: Power subsystem status changed to predictive failure.
Enclosure name: Power subsystem status changed to error.
Fan zone events
Enclosure name: Fan zone number status changed to non-recoverable error.
Enclosure name: Fan zone number status changed to predictive failure.
Enclosure name: Fan zone number status changed to error.
HP SNMP agent and HP CIM provider events
HP OneView for vCenter registers with HP SNMP agents and HP CIM providers to receive traps
from HP SNMP agents and indications from HP CIM providers as they occur. Events created based
on these traps and indications fit into the defined vCenter Server categories.
vCenter Server event category
Event severity
Event datasource type
Info
Normal or Information
HP SNMP agents or HP CIM providers
Warning
Warning or Minor
HP SNMP agents or HP CIM providers
Error
Major or Critical
HP SNMP agents or HP CIM providers
These events contain the following information:
•
Event source
•
Event name
•
Event category
•
Event description
Alarms
When an HP OneView for vCenter event is delivered to vCenter Server, the overall host status
changes based on the corresponding event category or the host status. An alarm is triggered when
the changes to the host status meet the criteria assigned by the administrator.
Overall host status
Event category
Green
Informational
Yellow
Warning
Red
Error
The following HP OneView for vCenter events can cause alarms in vCenter Server:
•
Alarms associated with the HP server SNMP traps
These alarms can be triggered by any event generated from an SNMP trap. The alarm states
are controlled by the event category.
•
Alarms associated with the HP server WBEM indications
These alarms can be triggered by any event generated from a WBEM indication. The alarm
states are controlled by the event category.
118
Viewing hardware alert notifications